0020262548_01 Operating instructions
5
3.4
Hybrid manager
If a heat pump and an additional boiler are connected, you
can use the hybrid manager. If there is a heat demand, the
hybrid manager picks the heat generator that is more cost-
efficient. The hybrid manager decides which heat generator
to operate based on the tariffs that are set in relation to the
heat demand.
To ensure that the heat pump and the boiler can work effect-
ively and in synch with one another, the tariffs (
must be set correctly. If the tariffs are set incorrectly, this res-
ults in increased costs.
3.5
Frost protection function
The frost protection function protects the heating installa-
tion and flat from frost damage. The frost protection function
monitors the outdoor temperature.
If the outdoor temperature
–
falls below 4 °C, the system control switches the heat
generator on after a frost protection delay time, and
brings the target room temperature to 5 °C.
–
rises above 5 °C, the system control does not switch the
heat generator on but monitors the outdoor temperature.
Note
The competent person can set the frost protection
delay time.
3.6
Preventing malfunctions
▶
Ensure that room air can circulate freely around the sys-
tem control, and that the system control is not covered by
furniture, curtains or other objects.
▶
Ensure that all thermostatic radiator valves in the room
where the system control is fitted are fully open.
3.7
Data plate
The data plate is located inside the product and is not ac-
cessible from the outside.
3.8
Serial number
You can call up the serial number to the display under
Menu
→
Information
→
Serial number
. The 10-digit article number
is located in the second line.
3.9
CE marking
The CE marking shows that the products comply with the
basic requirements of the applicable directives as stated on
the declaration of conformity.
The declaration of conformity can be viewed at the manufac-
turer's site.
4
Operation
4.1
Operating structure
4.1.1
Adjustment and display levels
The product has two adjustment and display levels.
The end user level contains information and setting options
that you require as the end user.
End user level (
The installer level is reserved for the competent person. It is
protected by a code. Only competent persons may change
any settings in the installer level.
4.1.2
Menu structure design
The menu structure consists of several selection levels and a
setting level.
You can always use the selection button
Menu
to access
selection level 1 from the basic display.
You can use the selection button
Op. mode
to directly ac-
cess the setting level
Operating mode
.
The lowest level is always the setting level.
4.1.3
Selection level
Menu
Information
Desired temperatures
Time programmes
Back
Select
1
2
2
3
4
1
Scroll bar
2
Current function of the
selection button
3
List entries on the se-
lection level
4
Current selection level
The scroll bar
(1)
only appears if there are more list entries
than can be shown at once on the display.
4.1.4
Setting level
ZONE1
Set-back temp. heat.
Day temp. cooling
Day temp. heating
Back
Change
20,0°C
26,0°C
15,0°C
2
2
3
1
4
1
Set values
2
Current function of the
selection button
3
Functions on the setting
level
4
Current selection level
You can read or change the set values in the setting level.
4.1.5
Soft key function for the selection buttons
Both selection buttons have a soft key function, i.e. different
functions may be assigned to the selection buttons. If, for ex-
ample, you press the left-hand selection button, the current
function switches from
Menu
to
Back
.