Installation manual remote control device VR 90 0020055329_00
Start-up 5
Displayed text
Adjustable parameters
Setting range
Default setting
heat zone 2-max heat zone 15
C2
Parameter
Type:
Mixing circuit
Night set back temp.
Heating curve
Max limit outs. temp
Minimum temp.
Maximum temp.
Max. pre-heat
Switch-on room temp.
Remote control
Target flow temp.
Current flow temp.
Status of pump
Status hydr. mixer
>select Night set back temp.
> 15°C
0,90
20°C
15°C
75°C
0 h
none
Yes
55°C
45°C
OFF
OFF
Set-back temperature
Heating curve
Maximum limit outside
temperature
Minimum temperature
Maximum temperature
Max. pre-warm-up time
Switch-on room temperature
5 - 30 °C
0.2 - 4
5 - 50 °C
15 - 90 °C
15 - 90 °C
0 - 5 h
none/intervention
15 °C
1.2
22 °C
15 °C
75 °C
0
none
Tool
C12
Temperature correction
Current room temp.
0,0 K
>Select correction value
Temperature correction:
Current room temperature
-3 ... +3 K
O K
Table 5.1 Settings on the code level (continued)