Operating manual Remote control device VR 90 0020055329_00
10
Displayed menu
Explanation and setting options
The following information is displayed on the basic display:
the current date and time, the outside temperature (if room modulation is activated),
the current room temperature, the current operating mode and the target room
temperature.
Each heating circuit or hot water circuit is controlled separately according to the
operating mode.
The heating, energy saving, auto, eco and off operating modes are available:
Auto
The selected circuit is operated automatically between the desired set
point and set back temperatures according to the on and off time
programmes.
Eco
The selected circuit is operated automatically between the desired set
point and fully off according to the on and off timer programmes. The
frost protection function will still activate if enabled.
Heating
The selected circuit operates continuously ‘on’ at the desired ‘on’
temperature set point, regardless of the programmed times.
Energy sav
The selected circuit operates continuously ‘on’ at the desired ‘off/setback’
temperature set point, regardless of the programme times.
Off
The selected circuit is continually off except for when frost protection is
activated..
Table 2.1 Adjustable parameters
2 Operation
Fr 17.05.02
heat zone 1
15:37
> heating
- 15°C
22°C
>select operation mode
room temperature
21° C