Operating and Installation Manual for Solar Module VR 68 0020054784_00
22
Display
screen
Title
screen
Adjustable
operating values
(only display = A)
Remarks
Unit
Min.
value
Max.
value
Increment or
possible
values
Preset
value
C17
Parameters
Solar circuit
Running time of
solar pump (A)
For monitoring of
maintenance intervals
Hrs
0
9999
1
0
Reset running times
Reset running time of
solar pump to 0 hrs
Yes, No
No
Pump activation
duration controlling
Adjustment of pump
output via activation
duration controlling or
timing device to
maintain the activation
temperature
differential for as long
as possible
On, Off
Off
C21
Total system
parameters
Mode Auto_OFF
Determines the heating
control outside the
programmed time
window
Frost
protection,
ECO, energy
sav
Frost
protection
Frost protection
delay time
Delayed start of frost
protection function or
ECO function
Hr
0
12
1
4
Max. pump blocking
time
If the feed target
temperature is
achieved for an
extended period, the
heating is switched off
for the prescribed
pump blocking time
(dependent upon the
outside temperature)
Min
Off, 5
60
1
15
C22
Total system
parameters
Max. advanced
heating time
Before the start of the
first time window
Min
0
300
10
0
Max. heating switch
off time
Before the end of a
time window
Min
0
120
10
0
AT through-heating
When the outside
temperature is
reached, continuous
heating is active
°C
OFF, -25
+10
1
Off
C24
Service
Telephone number
Entry of the telephone
number for the service
requirement
Changing the code
number
0000
9999
each 1
1000
Maintenance date
Day/Month/Year
adjustable
C25
Tools
Outside
temperature
correction
Matching of the
external sensor
R
-5
5
1,0
0
Room temperature
correction
Matching the room
temperature sensor
R
-3
3
0,5
0
Display contrast
0
15
1
6
C26
Software versions
Software-Version
VR 68 (A)
Display of version
number
Table 7.2 Display screens in the level for the expert technician
(continuation)
7 Start-up