Appendix

0020221300_04 uniSTOR HP Installation and maintenance instructions

17

C

Technical data

Technical data

General

VIH RW GB
150 BES

VIH RW GB
200 BES

VIH RW GB
250 BES

VIH RW GB
300 BES

Actual volumetric capacity

143.0 l

190.7 l

236.3 l

273.5 l

Hot water volumetric capa-
city in accordance with EN
12897

133.0 l

172.5 l

211.0 l

208.0 l

Maximum pressure of the
heating tube coil during op-
eration

0.35 MPa
(3.50 bar)

0.35 MPa
(3.50 bar)

0.35 MPa
(3.50 bar)

0.35 MPa
(3.50 bar)

Operating pressure

0.35 MPa
(3.50 bar)

0.35 MPa
(3.50 bar)

0.35 MPa
(3.50 bar)

0.35 MPa
(3.50 bar)

Maximum operating pressure

0.7 MPa
(7.0 bar)

0.7 MPa
(7.0 bar)

0.7 MPa
(7.0 bar)

0.7 MPa
(7.0 bar)

Pressure of the pressure
reducer

0.35 MPa
(3.50 bar)

0.35 MPa
(3.50 bar)

0.35 MPa
(3.50 bar)

0.35 MPa
(3.50 bar)

Opening pressure in the ex-
pansion relief valve

0.6 MPa
(6.0 bar)

0.6 MPa
(6.0 bar)

0.6 MPa
(6.0 bar)

0.6 MPa
(6.0 bar)

Temperature and pressure
expansion relief valve

0.7 MPa
(7.0 bar)

0.7 MPa
(7.0 bar)

0.7 MPa
(7.0 bar)

0.7 MPa
(7.0 bar)

Temperature and pressure
expansion relief valve

90

90

90

90

Load pressure in the expan-
sion vessel

0.3 MPa
(3.0 bar)

0.3 MPa
(3.0 bar)

0.3 MPa
(3.0 bar)

0.3 MPa
(3.0 bar)

Maximum temperature of the
heating circuit

95

95

95

95

Maximum domestic hot water
temperature

85

85

85

85

Heat loss (24 h), energy effi-
ciency class: C

1 kWh

1.22 kWh

1.41 kWh

1.59 kWh

Reheating time in accord-
ance with EN 12897

19.67 min

20.83 min

15.08 min

10.66 min

Reheating time (70%)

13.77 min

14.58 min

10.55 min

7.46 min

Reheating output

20.8 kW

26.0 kW

40.7 kW

52.5 kW

Flow rate

900 l/h

900 l/h

900 l/h

1,300 l/h

Pressure loss in the heat
exchanger

70 mbar

100 mbar

170 mbar

200 mbar

Volume of the heat
exchanger

5.6 l

7.7 l

12.92 l

15.20 l

Surface of the heat
exchanger

1.0 m

²

1.4 m

²

2.4 m

²

2.8 m

²

Volume of the expansion
vessel

12 l

18 l

25 l

25 l

Tilt measurement

1,150 mm

1,390 mm

1,640 mm

1,840 mm

Net weight

36.0 kg

45.0 kg

59.0 kg

67.5 kg

Weight including heating wa-
ter and domestic hot water

184.6 kg

243.4 kg

308.2 kg

356.2 kg

Technical data

Hydraulic connection

VIH RW GB
150 BES

VIH RW GB
200 BES

VIH RW GB
250 BES

VIH RW GB
300 BES

Diameter of the cold water
supply pipe

3/4"

3/4"

3/4"

3/4"

Hot water outlet

3/4"

3/4"

3/4"

3/4"

Heat generator heating flow

3/4

3/4

3/4

3/4

Heat generator heating re-
turn

3/4

3/4

3/4

3/4

Summary of Contents for uniSTOR VIH RW GB BES Series

Page 1: ...ation and maintenance instructions uniSTOR HP VIH RW GB BES GB IE Publisher manufacturer Vaillant GmbH Berghauser Str 40 D 42859 Remscheid Tel 492191 18 0 Fax 492191 18 2810 info vaillant de www vaill...

Page 2: ...ct dimensions 7 5 Installation 7 5 1 Installing the product 7 5 2 Hydraulic connection 8 5 3 Electrical installation 11 6 Start up 13 6 1 Setting the immersion heater thermostat 13 6 2 Cold water inle...

Page 3: ...ntenance instructions for the product and any other system com ponents installing and setting up the product in ac cordance with the product and system ap proval compliance with all inspection and mai...

Page 4: ...correct tool 1 4 5 Risk of material damage caused by frost Do not install the product in rooms prone to frost 1 4 6 Risk of injury due to the heavy weight of the product Make sure that the product is...

Page 5: ...ements of the appropriate Building Regu lations The Benchmark Checklist can be used to demon strate compliance with Building Regulations and should be provided to the customer for future reference Ins...

Page 6: ...ation area Select a sensible installation site and take into consideration the routing of the pipework system Install the cylinder as close as possible to the heat generator in order to minimise heat...

Page 7: ...mplete Refer ence point Quant ity Designation 1 1 Enclosed documentation 2 1 Tundish with retainer 3 1 3 port motorised valve 4 1 Safety group 5 1 Expansion vessel 6 1 Bag with accessories 7 1 Domesti...

Page 8: ...nd pres sure expansion relief valve 7 Domestic hot water outlet 8 Safety group 9 Tundish 10 Expansion vessel 11 Dry pocket for the tem perature sensor 12 Cold water inlet 13 Drain valve 5 2 1 Connecti...

Page 9: ...e 15 mm Length of the pipe between the temperature and pressure relief valve and the expansion relief valve 4 600 mm 6 Connect the cold water supply to the safety group 6 Diameter of the cold water su...

Page 10: ...p in a soakaway with a siphon Low drain pipework for example up to 100 mm above external surfaces car parks mead ows etc can be used provided that it is protected by a wire fence or something similar...

Page 11: ...ling through the product The product may be damaged by drilling work Do not drill through the product 70 60 50 40 70 60 50 40 1 3 2 4 1 3 2 4 1 2 3 4 1 Immersion heater 2 Immersion heater ther mostat...

Page 12: ...he cover for the electrics on the cylinder 2 Install a separate power supply for the immersion heater in accordance with the applicable standards 3 Use heat resistant cables for the immersion heater c...

Page 13: ...the primary circuit 1 Connect the thermostat for the primary circuit and the thermal cut out Diameter of the cable 1 5 mm Condition S plan 70 60 50 40 70 60 50 40 1 3 2 4 1 3 2 4 L N 2 1 3 2 2 4 4 1 8...

Page 14: ...r ator 3 Move the lever to AUTO 4 Remove the cover for the electrics 5 Set the product s thermostat and the immersion heater s thermostat Setting the thermostats 60 6 Start up the heat generator 7 Dra...

Page 15: ...pressure of the expansion vessel 1 Drain the product Page 15 2 Measure the pre charge pressure of the expansion ves sel at the vessel valve Condition Pressure 0 3 MPa 0 3 bar Top up the expansion ves...

Page 16: ...stat to 55 C 4 Replace the thermostat Irregular domestic hot water output at the valve 1 Defective expansion vessel 2 Thermal control 1 Set the expansion vessel 2 Interrupt the power supply of the pro...

Page 17: ...90 90 90 Load pressure in the expan sion vessel 0 3 MPa 3 0 bar 0 3 MPa 3 0 bar 0 3 MPa 3 0 bar 0 3 MPa 3 0 bar Maximum temperature of the heating circuit 95 95 95 95 Maximum domestic hot water tempe...

Page 18: ...230 V 50 Hz Immersion heater power 2 8 kW 2 8 kW 2 8 kW 2 8 kW Low loss header 230 240 V 50Hz 230 240 V 50Hz 230 240 V 50Hz 230 240 V 50Hz Thermostat 230 240 V 50Hz 230 240 V 50Hz 230 240 V 50Hz 230...

Page 19: ...Appendix 0020221300_04 uniSTOR HP Installation and maintenance instructions 19 D Commissioning Checklist...

Page 20: ...WUROV KDYH EHHQ WWHG LQ FRPSOLDQFH ZLWK 3DUW RI WKH XLOGLQJ 5HJXODWLRQV Yes Type of control system if applicable Y Plan S Plan Other Is the cylinder solar or other renewable compatible Yes No What is...

Page 21: ...3 Date Engineer name Company name Telephone No Comments Signature SERVICE 05 Date Engineer name Company name Telephone No Comments Signature SERVICE 07 Date Engineer name Company name Telephone No Com...

Page 22: ...ipe 9 Documents 5 Drain valve 8 Draining the product 15 E Electricity 3 F Filling and purging the primary circuit 14 Filling and purging the product 14 Frost 4 H Handing over to the end user 14 I Iden...

Page 23: ......

Page 24: ...byshire DE56 1JT Telephone 0330 100 3461 info vaillant co uk www vaillant co uk These instructions or parts thereof are protected by copyright and may be reproduced or distributed only with the manufa...

Reviews: