background image

Safety 1

0020208984_00 turboMAG pro Operating instructions

3

1

Safety

1.1

Action-related warnings

Classification of action-related warnings

Warning symbols and signal words

The action-related warnings are classified in

accordance with the severity of the possible

danger using the following warning signs and

signal words:

Danger!

Imminent danger to life or risk of

severe personal injury

Danger!

Risk of death from electric shock

Warning.

Risk of minor personal injury

Caution.

Risk of material or environmental

damage

1.3.1 Intended use

There is a risk of injury or death to the user or

others , or of damage to the product and other

property in the event of improper use or use

for which it is not intended.

The products are gas-fired instantaneous

water heaters and, as such, are intended for

hot water generation.
Intended use includes the following:

observance of the operating instructions

included for the product and any other

system components

compliance with all inspection and main-

tenance conditions listed in the instruc-

tions.

This product can be used by children over

eight years old and also by persons with lim-

ited physical , sensory or mental capabilities

or insufficient experience and/or knowledge

if they are supervised or have been provided

with instructions on how to safely use the

product , and they understand the risks res -

ulting from using the product. Children must

not play with the product. Cleaning and user

maintenance work must not be carried out by

children unless they are supervised.
Any other use that is not specified in these

instructions , or use beyond that specified in

this document shall be considered improper

use. Any direct commercial or industrial use

is also deemed to be improper.

Caution.

Improper use of any kind is prohibited.

1.3.2 Installation by competent persons

only

Only an approved competent person is per-

mitted to carry out installation, inspection,

maintenance and repair work on the prod-

uct.

1.3.3 Danger caused by improper operation

Improper operation may present a danger to

you and others, and cause material damage.

Carefully read the enclosed instructions

and all other applicable documents , par-

ticularly the "Safety" section and the warn-

ings.

1.3.4 Risk of death due to blocked or

leaking flue gas routes

What to do if you smell flue gas in the prop-

erty:

1.2

Required personnel qualifications

Caution.

This product must only be used after the flue

pipe that is routed to the outside has been

installed.
According to the Hong Kong Gas Safety Reg-

ulations, Cap.51, any gas installation works

including the installation of appliances and

connecting tubing , must be undertaken by

Registered Gas Installers who are registered

for that appropriate classes and be employed

by Registered Gas Contractors.
Improper work carried out on the product

may cause material damage to the complete

installation and, as a consequence, may even

cause personal injury.

You should therefore only work on the

product if you are an authorised competent

person.

1.3

General safety information

Note

In these instructions , the  Registered

Gas Installer is referred to throughout

as "competent person".

Summary of Contents for MAG HK 13-2/0-3 B

Page 1: ...Berghauser Str 40 D 42859 Remscheid Telefon 02191 18 0 Telefax 021 91 18 28 10 info vaillant de www vaillant de Operating instructions MAG HK 13 2 0 3 H back flue MAG HK 13 2 0 3 B back flue MAG HK 17 2 0 3 H back flue MAG HK 17 2 0 3 B back flue MAG HK 13 2 0 3 H top flue MAG HK 13 2 0 3 B top flue For the operator ...

Page 2: ...3 6 Recommended hot water temperature settings 6 4 Operation 7 4 1 Preparing for start up 7 4 2 Starting up the product 7 4 3 Switching on the product 7 4 4 Selecting operating modes 7 4 5 Setting the normal operating mode 7 4 6 Setting ECO mode 7 4 7 Stopping ECO mode 8 4 8 Setting the bath filling mode 8 4 9 Exiting bath filling mode 8 4 10 Setting the priority for the remote controls 8 5 Detect...

Page 3: ...be carried out by children unless they are supervised Any other use that is not specified in these instructions or use beyond that specified in this document shall be considered improper use Any direct commercial or industrial use is also deemed to be improper Caution Improper use of any kind is prohibited 1 3 2 Installation by competent persons only Only an approved competent person is per mitted...

Page 4: ...e gas installation to the expansion relief valve to the drain lines to constructional conditions that may affect the operational reliability of the product 1 3 9 Risk of injury and material damage due to maintenance and repairs carried out incorrectly or not carried out at all Never attempt to carry out maintenance work or repairs on your product yourself Faults and damage should be immediat ely r...

Page 5: ...bsolutely sure that the product is compat ible with the gas group at the installation site 3 2 Output ranges Type designation Power Water flow rate ΔT 25 K MAG HK 13 2 0 3 H back flue MAG HK 13 2 0 3 H top flue MAG HK 13 2 0 3 B back flue MAG HK 13 2 0 3 B top flue Min 4 8 max 28 kW 13 L min MAG HK 17 2 0 3 H back flue MAG HK 17 2 0 3 B back flue Min 6 2 max 37 kW 17 L min 3 3 Product design 1 2 3...

Page 6: ... water temperature settings 38 39 40 41 42 43 44 45 46 47 48 49 70 1 2 3 1 Washing dishes showering 2 Showering hot water 3 High temperature The hot water temperature can be set from 38 C to 70 C default setting 42 C If the water temperature that is set is below 48 C before hot water generation begins youcannot increase the hot water temperature to above 48 C during operation this is to prevent sc...

Page 7: ...Switch on the power supply to the product 6 Open the gas isolator cock 2 4 2 Starting up the product Only start up the product once the casing has been com pletely closed 4 3 Switching on the product 1 Press The display shows the preset temperature in the normal operating mode default setting 42 C Once the self test is complete the display goes off and the product goes into standby mode 2 Open the...

Page 8: ... elements on the product Alternatively on a remote control briefly press the button to prior itise the remote control The symbol displaying the prioritisation lights up on the display Displayed symbols Page 6 5 Detecting and rectifying faults Fault messages have priority over all other displays If faults occur or fault messages are displayed proceed as set out in the table in the appendix Detectin...

Page 9: ...mis sion the product 8 Guarantee and customer service 8 1 Guarantee For information on the manufacturer s guarantee you can write to the contact address that is provided on the back page 8 2 Customer service For contact details for our authorised customer service de partment you can write to the address that is provided on the back page or you can visit www vaillant com ...

Page 10: ...Discharge the cold water Vapour at the flue gas open ing The water in the flue gas condenses in the cold air Hot water is white Air that is dissolved in the cold water escapes After closing the hot water valve the ventilator contin ues running Ventilator supplies the burner with outside air Fluctuating water temperat ure and flow rate Additional water taps are opened or closed No fault Water leak ...

Page 11: ......

Page 12: ...0020208984_00 21 04 2015 These instructions or parts thereof are protected by copyright and may be reproduced or distributed only with the manufacturer s written consent ...

Reviews: