Electrical installation
Installation instructions geoTHERM 0020051574_04
63
7
supply line through the opening in the upper part of the
front cladding (
1
).
b
Caution!
Risk of short-circuit caused by a free
voltage supply cable.
If you do not use the vrnetDIALOG acces-
sory or voltage is not supplied to the vrnet-
DIALOG via the heat pump, the free con-
nector -vrnetDIALOG (230 V voltage sup-
ply) may cause short circuits within the
heat pump.
>
Leave the connection cable -vrnetDIA-
LOG (230 voltage supply) in the fastening
of the heat pump.
>
Hook the upper part of the front cladding onto the frame
and push it into the clip holder.
>
Use two screws to secure the upper part of the front
cladding.
7.27 Fitting the operating panel
>
Push the operating panel into the clip holder on the
mounting plate and then screw in the operating panel
from the rear.
1.
2.
2.
7.28 Fitting the lower part of the front cladding
>
Place the lower part of the front cladding on the frame
of the heat pump.
>
Guide the eBUS line for the operating panel and, if you
are using the vrnetDIALOG accessory, the 230 V voltage
supply line through the opening in the mounting plate of
the operating panel.
>
Then push the cladding into the clip holder on the side
cladding.
>
Tightly screw on the mounting plate for the operating
panel as you did with the two screws for the upper part
of the front cladding.
>
If you want to fit the vrnetDIALOG accessory, you must
first carry out the assembly steps in
(
¬
Ch. 7.10
) before
continuing to fit the cladding.