8 Decommissioning

14

Operating instructions flexoTHERM 0020213396_00

Min. heating circuit pressure:

0.05 MPa (

0.50 bar)

Min. heating circuit operating pressure:

0.07 MPa (

0.70 bar)

Inform your competent person so that
he can top up the heating water.

8 Decommissioning

8.1 Switching off the heat pump
8.1.1 Temporarily decommissioning

the product

Use the partition that is installed on-
site (e.g. fuses or power switches) to
disconnect the product from the power
supply.

8.1.2 Protecting the product against

frost

Observe the installation site require-
ments for the product. (

Page 13)

8.2 Permanently

decommissioning the product

1. Have a competent person permanently

decommission the product.

2. Have the product disposed of by a

competent person.

8.3 Recycling and disposal

The competent person who installed
your product is responsible for the dis-
posal of the packaging.

If the product is identified with this

symbol:

In this case, do not dispose of the
product with the household waste.

Instead, hand in the product to a collec-
tion centre for old electrical or electronic
appliances.

If the product contains batteries that

are marked with this symbol, these bat-
teries may contain substances that are

hazardous to human health and the envir-
onment.

In this case, dispose of the batteries at
a collection point for batteries.

8.3.1 Arranging disposal of the

brine fluid

The product is filled with the brine fluid
ethylene glycol, although when using
ground as the heat source, aqueous
solutions of propylene glycol may also be
used as an alternative. Ethylene glycol is
harmful to health.

Brine fluid must only be disposed of by
a qualified competent person.

8.3.2 Arranging disposal of coolant

The product is filled with R 410 A refriger-
ant.
The coolant must not be allowed to escape
into the atmosphere.

Coolant must only be disposed of by a
qualified competent person.

9 Guarantee and customer

service

9.1 Guarantee

Applicability:

Great Britain

Vaillant provides a full parts and labour
guarantee for this appliance for the dura-
tion as shown on the enclosed registration
card which must be fully completed and
returned within 30 days of installation. All
appliances must be installed by a suitably
competent person fully conversant and
in accordance with all current regulations
applicable to the appliance type installa-
tion. In the case of gas appliances the Gas
Safety (Installation and Use) Regulations
1998, and the manufacturer’s instructions.
In the UK competent persons approved at
the time by the Health and Safety Execut-
ive undertake the work in compliance with

Summary of Contents for flexoTHERM VWF 5x

Page 1: ...erating instructions flexoTHERM VWF 5x 19x 4 GB IE Operating instructions Publisher manufacturer Vaillant GmbH Berghauser Str 40 D 42859 Remscheid Tel 49 21 91 18 0 Fax 49 21 91 18 28 10 info vaillant...

Page 2: ...4 9 Menu display 11 4 10 Operating levels 12 5 Operating 12 5 1 Starting up the product 12 5 2 Adjusting the target cylinder temperature 12 5 3 Yield indicator 12 5 4 Displaying the Live Monitor 12 5...

Page 3: ...ended exclus ively for domestic use The system is intended as a heat generator with cooling function for closed central heat ing installations and for hot wa ter generation Operation of the pump outsi...

Page 4: ...ocuments particu larly the Safety section and the warnings 1 2 3 Risk of death due to explosive and flammable materials Do not use or store explosive or flammable materials e g petrol paper paint in t...

Page 5: ...t at all Never attempt to carry out maintenance work or repairs on your product yourself Faults and damage should be immediately rectified by a competent person Adhere to the maintenance intervals spe...

Page 6: ...ons Ensure that only officially cer tified competent persons with appropriate protective equip ment carry out maintenance work on the refrigerant circuit or access it Arrange for the refriger ant that...

Page 7: ...se 2 3 Applicability of the instructions These instructions apply only to Applicability Great Britain OR Ireland Product VWF 57 4 VWF 87 4 VWF 117 4 VWF 157 4 VWF 197 4 Applicability Great Britain OR...

Page 8: ...emperat ure drops below a certain value The outlet temperature of the heat source is constantly measured If the outlet tem perature of the heat source falls below a certain value the compressor tempor...

Page 9: ...equirement without switching off prematurely 60 minutes of uninterrupted operation 4 2 8 Safety cut out SCO in the heating circuit If the temperature in the heating circuit of the internal auxiliary e...

Page 10: ...pump 9 Display 4 7 Basic display 50 d kWh Sym bol Meaning Explanation Compressor Filled Com pressor in op eration Not filled Compressor not in operation bar Current filling pressure of the heating sy...

Page 11: ...fault message 4 8 Operating concept Op erator control element Function Displaying the environmental energy yield in heating mode hot water handling mode and cooling mode Cancelling a change to a set...

Page 12: ...ating hot water generation and cooling modes Displays the working figure for a period of a month and the total for the heating and hot water generation modes The work ing figure is the ratio of therma...

Page 13: ...hlorine Clean the casing with a damp cloth and a little solvent free soap 6 1 3 Checking the system pressure Check the filling pressure of the heating installation every day for a week after initial s...

Page 14: ...s that are hazardous to human health and the envir onment In this case dispose of the batteries at a collection point for batteries 8 3 1 Arranging disposal of the brine fluid The product is filled wi...

Page 15: ...r antee details of which can be found on the registration card included with this appli ance In order to qualify for guarantee after one year the appliance must be serviced in accordance with our inst...

Page 16: ...h Working figure Total Heating Cumulative value Energy yield Month Domestic hot water Cumulative value kWh Working figure Month Domestic hot water Cumulative value Energy yield Total Domestic hot wate...

Page 17: ...g rod power Current value kW Information Contact data Phone number Serial number Permanent value Operating hours total Cumulative value h Hours heating Cumulative value h DHW operating hours Cumulativ...

Page 18: ......

Page 19: ......

Page 20: ...les 02 07 022 09 28 Vaillant Service Solutions 03 30 100 31 43 Spares Technical Enquiries 017 73 59 66 15 info vaillant co uk technicalspares groupservice co uk www vaillant co uk These instructions o...

Reviews: