background image

4 Product description

10

Operating instructions flexoTHERM 0020213396_00

4.6 Operator control panel

50

d

kWh

reset

1

2

3

4

6

7

8

9

5

1

Displays the
daily environ-
mental energy
yield

2

Display of the
current as-
signment of
the right-hand
selection button

3

Left- and right-
hand selection
buttons

4

and

but-

ton

5

Reset button

6

Access to the
menu for addi-
tional information

7

Display of the
current configur-
ation of the left-
hand selection
button

8

Displays the
symbols for the
current operat-
ing status of the
heat pump

9

Display

4.7 Basic display

50

d

kWh

Sym-
bol

Meaning

Explanation

Compressor

Filled: Com-
pressor in op-
eration

Not filled:
Compressor
not in
operation

bar

Current filling
pressure of the
heating system
The dashed lines
show the permit-
ted range.

Permanently
on: Filling
pressure in
the permitted
range.

Flashing:
Filling pres-
sure outside
the permitted
range.

Pumps

Left continu-
ously on: Brine
pump in oper-
ation

Right con-
tinuously on:
Heating pump
in operation

Auxiliary electric
heating

Flashing: Aux-
iliary electric
heating in op-
eration

+ : Aux-

iliary electric
heating act-
ive for heating
mode

+

: Aux-

iliary electric
heating active
for hot water
handling mode

Green iQ mode

Product
equipped with
energy-saving
technology

Summary of Contents for flexoTHERM VWF 5x

Page 1: ...erating instructions flexoTHERM VWF 5x 19x 4 GB IE Operating instructions Publisher manufacturer Vaillant GmbH Berghauser Str 40 D 42859 Remscheid Tel 49 21 91 18 0 Fax 49 21 91 18 28 10 info vaillant...

Page 2: ...4 9 Menu display 11 4 10 Operating levels 12 5 Operating 12 5 1 Starting up the product 12 5 2 Adjusting the target cylinder temperature 12 5 3 Yield indicator 12 5 4 Displaying the Live Monitor 12 5...

Page 3: ...ended exclus ively for domestic use The system is intended as a heat generator with cooling function for closed central heat ing installations and for hot wa ter generation Operation of the pump outsi...

Page 4: ...ocuments particu larly the Safety section and the warnings 1 2 3 Risk of death due to explosive and flammable materials Do not use or store explosive or flammable materials e g petrol paper paint in t...

Page 5: ...t at all Never attempt to carry out maintenance work or repairs on your product yourself Faults and damage should be immediately rectified by a competent person Adhere to the maintenance intervals spe...

Page 6: ...ons Ensure that only officially cer tified competent persons with appropriate protective equip ment carry out maintenance work on the refrigerant circuit or access it Arrange for the refriger ant that...

Page 7: ...se 2 3 Applicability of the instructions These instructions apply only to Applicability Great Britain OR Ireland Product VWF 57 4 VWF 87 4 VWF 117 4 VWF 157 4 VWF 197 4 Applicability Great Britain OR...

Page 8: ...emperat ure drops below a certain value The outlet temperature of the heat source is constantly measured If the outlet tem perature of the heat source falls below a certain value the compressor tempor...

Page 9: ...equirement without switching off prematurely 60 minutes of uninterrupted operation 4 2 8 Safety cut out SCO in the heating circuit If the temperature in the heating circuit of the internal auxiliary e...

Page 10: ...pump 9 Display 4 7 Basic display 50 d kWh Sym bol Meaning Explanation Compressor Filled Com pressor in op eration Not filled Compressor not in operation bar Current filling pressure of the heating sy...

Page 11: ...fault message 4 8 Operating concept Op erator control element Function Displaying the environmental energy yield in heating mode hot water handling mode and cooling mode Cancelling a change to a set...

Page 12: ...ating hot water generation and cooling modes Displays the working figure for a period of a month and the total for the heating and hot water generation modes The work ing figure is the ratio of therma...

Page 13: ...hlorine Clean the casing with a damp cloth and a little solvent free soap 6 1 3 Checking the system pressure Check the filling pressure of the heating installation every day for a week after initial s...

Page 14: ...s that are hazardous to human health and the envir onment In this case dispose of the batteries at a collection point for batteries 8 3 1 Arranging disposal of the brine fluid The product is filled wi...

Page 15: ...r antee details of which can be found on the registration card included with this appli ance In order to qualify for guarantee after one year the appliance must be serviced in accordance with our inst...

Page 16: ...h Working figure Total Heating Cumulative value Energy yield Month Domestic hot water Cumulative value kWh Working figure Month Domestic hot water Cumulative value Energy yield Total Domestic hot wate...

Page 17: ...g rod power Current value kW Information Contact data Phone number Serial number Permanent value Operating hours total Cumulative value h Hours heating Cumulative value h DHW operating hours Cumulativ...

Page 18: ......

Page 19: ......

Page 20: ...les 02 07 022 09 28 Vaillant Service Solutions 03 30 100 31 43 Spares Technical Enquiries 017 73 59 66 15 info vaillant co uk technicalspares groupservice co uk www vaillant co uk These instructions o...

Reviews: