8 Decommissioning
14
Operating instructions flexoTHERM exclusive 0020213396_02
▶
Inform your competent person so that
he can top up the brine fluid.
F.723 Building circuit: Pressure too low
If the filling pressure falls below the min-
imum pressure, the heat pump will be
switched off automatically.
–
Min. heating circuit pressure:
≥
0.05 MPa (
≥
0.50 bar)
–
Min. heating circuit operating pressure:
≥
0.07 MPa (
≥
0.70 bar)
▶
Inform your competent person so that
he can top up the heating water.
F.1120 Heating rod: Phase failure
The product has an internal circuit breaker
which switches off the heat pump in the
event of short circuits or the failure of
one (product with 230 V power supply) or
several (product with 400 V power supply)
current-carrying phases. This may be
caused by a defect in the internal auxiliary
electric heater, for example.
If the auxiliary electric heater is defective,
the Anti-legionella function is not guaran-
teed.
▶
Inform your competent person so that
they can rectify the fault and reset the
internal circuit breaker.
8 Decommissioning
8.1 Switching off the heat pump
8.1.1 Temporarily decommissioning
the product
▶
Use the partition that is installed on-
site (e.g. fuses or power switches) to
disconnect the product from the power
supply.
8.1.2 Protecting the product against
frost
▶
Observe the installation site require-
ments for the product. (
→
Page 13)
8.2 Permanently
decommissioning the product
1. Have a competent person permanently
decommission the product.
2. Have the product disposed of by a
competent person.
8.3 Recycling and disposal
▶
The competent person who installed
your product is responsible for the dis-
posal of the packaging.
If the product is identified with this
symbol:
▶
In this case, do not dispose of the
product with the household waste.
▶
Instead, hand in the product to a collec-
tion centre for old electrical or electronic
appliances.
If the product contains batteries that
are marked with this symbol, these bat-
teries may contain substances that are
hazardous to human health and the envir-
onment.
▶
In this case, dispose of the batteries at
a collection point for batteries.
8.3.1 Arranging disposal of the
brine fluid
The product is filled with the brine fluid
ethylene glycol, although when using
ground as the heat source, aqueous
solutions of propylene glycol may also be
used as an alternative. Ethylene glycol is
harmful to health.
▶
Brine fluid must only be disposed of by
a qualified competent person.
8.3.2 Arranging disposal of coolant
The product is filled with R 410 A refriger-
ant.
The coolant must not be allowed to escape
into the atmosphere.