Installation 5
0020244339_01 eloSTOR plus, eloSTOR exclusive Installation and maintenance instructions
7
5L O
5L U
Dimen-
sion (f)
218 mm
218 mm
Dimen-
sion (g)
232 mm
232 mm
Dimen-
sion (h)
335 mm
104 mm
4.3
Wall-mounting the product
1.
Drill the holes in the wall for the rawl plugs.
Applicability:
Installation above the work surface
A
B
▶
Use the appropriate fixing material to secure the
product to the wall as shown in the illustration.
Applicability:
Installation below the work surface
A
B
▶
Use the appropriate fixing material to secure the
product to the wall as shown in the illustration.
Conditions
: The load-bearing capacity of the wall is sufficient, The
fixing material may be used for the wall
▶
Wall-mount the product as described.
Conditions
: The load-bearing capacity of the wall is not sufficient
▶
Ensure that wall-mounting apparatus on-site has a
sufficient load-bearing capacity. Use individual stands
or primary walling, for example.
▶
Do not wall-mount the product if you cannot provide
wall-mounting apparatus with a sufficient load-bearing
capacity.
5
Installation
Danger!
Risk of scalding and/or risk of material
damage due to incorrect installation lead-
ing to escaping water.
Stresses in supply lines can cause leaks.
▶
Install the supply lines without tension.
5.1
Establishing the water connection
Applicability:
Installation above the work surface
1
2
3
4
1
Cold water inlet
2
Hot water flow
3
Cold water inlet
4
Power supply
▶
Check the water pressure.
◁
The water pressure is, at most, as great as the
max. permissible pressure.
–
Water pressure:
≤
0.5 MPa (
≤
5.0 bar)
▽
If the water pressure is greater than the max. per-
missible pressure, install a domestic pressure reg-
ulator.