15
Installation instructions for the electronicVED plus electric instantaneous water heater 0020149585_00
5.3.1
Calling up the installer menu
>
Press and hold the
MEMO
button for longer than
3 seconds to reach the installer menu.
Appliance data
Remote control
ok
Using this menu, you have access to the current and
cumulated
Appliance data
.
5.3.2 Displaying unit parameters
You are in the installer menu. The cursor is next to the
Appliance data
menu point.
>
Press the
ok
button.
Appliance data
current
cumulated
ok
The cursor is next to the
current
menu point.
>
Press the
ok
button.
Current appl. data
Inlet temp.
21 °C
Desired temp.
38 °C
Outlet temp.
---
Output
12.0 kW
Flow rate
8.0 l/min
ok
The following information is displayed:
Inlet temp.
The current temperature of the
drinking water, as measured at the
unit's cold water inlet.
Desired temperature
The target temperature set on the
unit for the hot water output.
Outlet temp.
The current temperature of the
hot water, as measured at the hot
water outlet.
Output
The unit's current output, meas-
ured in kilowatts.
Flow rate
The current flow rate, measured in
litres per minute.
Tab. 5.1 Current appliance data
>
Press the
button to return to the
Appliance data
menu.
The cursor is next to the
current
menu point.
>
Press the
button.
The cursor is next to the
cumulated
menu point.
>
Press the
ok
button. The cumulated appliance data
will be displayed.
Appl. data history
Operated time
548 h
Period of use
112 h
Energy 107
kW
Water 2538
Litres
ok
Starting up/decommissioning 5
Summary of Contents for electronicVED plus
Page 1: ...Operating and installation instructions EXP electronicVED plus...
Page 2: ......
Page 3: ...For the operator Operating instructions electronicVED plus Electric instantaneous water heater...
Page 18: ......
Page 38: ......
Page 39: ......
Page 40: ...0020149585_00 EXPen 072012 Subject to change Manufacturer...