eletronicVED pro series 

5  Water heater use

4�4 

Special points related to installation

Clean the pipe by water before installation to prevent 

residual sediment from clogging the appliance 

 - Water heater inlet could be either upward or downward. 

Water heater will not work normally if the inlet is on the 

left or right.

 - Filter shall be installed at the inlet. Filter is included in 

gasket package. - Fix hanging bracket at the appliance 

installation position inside the cabinet. The appliance 

should directly hang on the bracket.

 - Connect water heater power line and power line on the 

wall by wiring board.

 - After completing installation, please open the water 

firstly without turning on the power.

 - Turn on the power when outlet water flows smoothly 

without bubbles.

 - miniVED plus temperature can be adjusted by using plus 

and minus buttons. (normal the temperature setting is 

38℃).

 - Display temperature will blink if the water temperature 

can’t reach the setting temperature then the water flow 

needs to be reduced. 

 - When using miniVED plus, use only hot water and do 

not mix hot and cold water.

 - 2.5 mm² copper core electric wires are required for 

installation. Air-break switch ≥25A.

Water heater use

5�1 

Usage of water heater

After installation of water heater, please turn on water 

mixing tap. Only after confirming that outlet water flows 

continuously and there is no water leakage at each joints 

can the water heater be turned on.

 

Starting up

Close the air-break switch (only for the first time use after 

installation), adjust the water mixing tap to the appropriate 

flow.

 - miniVED plus series:

Press the "ON/ OFF" button, the display is bright, and enter 

the instant heating mode. The display shows the current 

setting temperature.

 - miniVED pro series:

Turn on the water tap and start heating.

 

miniVED plus series (VED E 6/1-P IN)

This appliance is a constant temperature type. The default 

setting temperature is 38℃.

 

miniVED pro series (VED E 6/1-B IN)

This appliance has built-in power constant setting, adjusting 

the outlet temperature by adjusting the mixing tap.

 

Temperature adjustment (miniVED plus)

The water temperature is adjusted by "+" button of 

temperature, and 1℃ rise by one press until 48℃ ; the 

temperature "-" button is adjusted to reduce the water 

temperature, 1 ℃ down by one press. The temperature 

adjustment range for users is 30℃-48℃.

 

Turn off the appliance

After using the appliance, press lightly OFF to turn off the 

appliance (miniVED plus).

Turn off the appliance by turning off the water mixing tap 

(miniVED pro).

Water heater maintenance

The power supply must be disconnected before cleaning 

the water heater. Use a damp cloth to dip a small amount of 

neutral detergent and gently wipe the water heater, do not 

use gasoline or other solutions. Dry the water heater with a 

dry cloth and keep the water heater dry.

Caution�

The water heater is heated only when the water 

flows and the flow rate is larger than 2L/ Min.

Summary of Contents for EIWH mini VED plus

Page 1: ... PLQL 9 VHULHV 9 3 1 9 1 7R XVHUV SURIHVVLRQDOV 2SHUDWLQJ DQG LQVWDOODWLRQ LQVWUXFWLRQV 2SHUDWLQJ DQG LQVWDOODWLRQ LQVWUXFWLRQV ...

Page 2: ...ructions 5 2 3 Appliance type 5 3 Product description 5 3 1 Main components 5 3 2 Product features 5 4 Installation 6 4 1 Packing list 6 4 2 Installation method 6 4 3 Technical parameters 7 4 4 Special points related to installation 8 5 Water heater use 8 5 1 Usage of water heater 8 6 Water heater maintenance 8 7 Troubleshooting 9 8 Recycling and disposal 10 9 Guarantee and customer service 10 9 1...

Page 3: ... Only persons from professional company who are sufficiently qualified are allowed to conduct installation commissioning maintenance and repairing of Vaillant EIWH mini VED plus pro It is only allowed to install Vaillant EIWHmini VED plus pro according to the instructions When the appliance is frozen or suspected to be frozen don t switch on the appliance until it is thawed Please check if the ele...

Page 4: ...miniVED plus pro is only used to heat domestic water The domestic water shall comply with national domestic water quality requirement otherwise the appliance may rust If you have any doubts about the water quality please consult the professional Risk of freezing If EIWH mini VED plus pro is kept in non heated area for a long time the water inside the appliance and pipe may freeze in winter Ensure ...

Page 5: ...ation work is finished 3 Product description 3 1 Main components 3 1 1 miniVED plus series VED E 6 1 P IN Fig 3 1 miniVED plus series main components Remark 3 1 2 miniVED pro series VED E 6 1 B IN Fig 3 2 mini VED pro series main components Reamrk 3 2 Product features 3 2 1 miniVED plus series Temperature control built in constant temperature mode default temperature is 38 The water heater include...

Page 6: ...sition of water heater Confirm water heater installation position according to water connection and electrical connections The installation position of the water heater is not more than 50mm from the power cord connection and not more than 50mm from the cold water outlet Use the hanging bracket fixing it to the wall with screws or directly fix the water heater to the wall with screws Fig 4 1 Water...

Page 7: ... controller 2 Heating body 3 Control panel 4 Display board 3 T cock 4 Cold water nozzle 5 Temperature sensor 6 Flow sensor 7 Water resistence detection 1 Temperature controller 2 Heating body 3 Control panel 4 Temperature sensor 5 Flow sensor 6 Water resisitence detection QOHW 2XWOHW Product type VED E 6 1 P IN VED E 6 1 B IN Rated voltage V Rated frequency Hz 220 50 220 50 Rated power kW 5 5 5 5 ...

Page 8: ... there is no water leakage at each joints can the water heater be turned on Starting up Close the air break switch only for the first time use after installation adjust the water mixing tap to the appropriate flow miniVED plus series Press the ON OFF button the display is bright and enter the instant heating mode The display shows the current setting temperature miniVED pro series Turn on the wate...

Page 9: ...E1 Outlet water temperature sensors short circuit or open circuit Check outlet water temperature sensor by a professional E2 Inlet water temperature sensor short circuit or open circuit Check the inlet water temperature sensor by a professional E5 Overheating sensor short circuit or open circuit Check by a professional E7 1 Medium detection short circuit or open circuit 2 Water resistance too high...

Page 10: ...electronic appliances If the product contains batteries that are marked with this symbol these batteries may contain substances that are hazardous to human health and the environment In this case dispose of the batteries at a collection point for batteries 9 Guarantee and customer service 9 1 Guarantee For information on the manufacturer s guarantee you can write to the contact address that is pro...

Page 11: ......

Page 12: ...ce Building Bhandarkar Road Lane 11 Deccan Pune 411 004 TEL 91 9619506391 cs aquagreensolutions in These instructions or parts thereof are protected by copyright and may be reproduced or distributed only with the manufacturer s written consent ...