background image

eletronicVED pro series 

3

Safety  1

Safety

1�1 

Classification of action-related warnings

The action-related warnings are classified in 

accordance with the severity of the possible danger 

using the following warning signs and signal words:

Table 1.1 Warning symbols and symbol words

1�2 

Intended use

Vaillant EIWH miniVED plus/pro comply with current 

technology and safety requirements.

There is a risk of injury or death to the users or others, 

or of damage to the product and other property in 

the event if improper use or use for which it is not 

intended.

The appliance is not designed to be used by persons 

limited in physical, sensory or mental capacity 

(including children) or persons lacking experience and 

/ or knowledge unless there are guardians to explain 

how to use the equipment to those persons.

Children must be taken care of to ensure that they will 

not play with the appliance.

Vaillant EIWH miniVED plus/pro is only allowed to 

heat domestic water. Vaillant EIWH miniVED plus/

pro is only suitable for household use of frost free 

closed indoor. Vaillant EIWH miniVED plus/pro is not 

intended as hot water circulation system.

Any other use that is not specified in these 

instructions, or use beyond that specified in this 

document shall be considered improper use. Any 

direct commercial or industrial use is also deemed to 

be improper. 

The manufacturer/supplier is not responsible for 

damage caused by improper use. The users also shall 

bear the risk alone.

Intended use including the following:

 - Observance of accompanying operating, 

installation and maintenance instructions for the 

product and any other system components

 - Compliance with all inspection and maintenance 

conditions listed in the instructions. 

1�3 

General safety information

Installation, operating, maintenance and repair

Only persons from professional company who 

are sufficiently qualified are allowed to conduct 

installation, commissioning, maintenance and 

repairing of Vaillant EIWH mini VED plus/pro. It is 

only allowed to install Vaillant EIWHmini VED plus/pro 

according to the instructions. 

 

When the appliance is frozen or suspected to be 

frozen, don’t switch on the appliance until it is 

thawed.

 

Please check if the electrical meter type and 

its capacity meets the    requirements of the 

purchased appliance.

 

Please make sure that air switch rating value of 

main power control box is no lower than C25.

 

Connect the water supply and check if it is 

unobstructed. Connect the circuit after confirm that 

there is no leakage.

 

Good grouding.

 

Please distribute power separately when decorating 

the bathroom (depending on the installation position 

of EIWH) and embed a copper core dedicated line 

between the main switch and the bathroom that 

meets the requirements of the appliance.

 

The appliance shall be installed on the solid wall. 

The gap between appliance and the wall surface 

shall be 3mm.

 

Please stop using the appliance immediately when 

the water flow stops.

 

Please reserve water inlet and outlet piping.

Risk of death from electric shock due to power 

supply wire and connector

When performing all operations on working appliance, 

especially on power supply wire and connector, there 

is risk of death caused by electric shock.

 

Users are allowed to disassemble the appliance.

Warning 

symbols

Signal 

words

Explanation

Danger!

Imminent danger to life or risk of 

severe personal injury

Danger!

Risk of death from electric 

shock

Warning. Risk of minor personal injury

Caution. Risk of material or 

environmental damage

Caution�

Prohibit any improper use.

mini VED 

power

electrical meter type

 and capacity (A)

5.5 kW

General  

electrical meter

Intelligent 

electrical meter

Mechanical 

electrical 

meter 

≥5/40

≥10/60

≥5/40

mini VED power

Air-break switch 

parameter(A)

5.5 kW

≥25

mini VED power

Dedicated copper line cross 

section (mm²)

5.5 kW

≥2.5

Summary of Contents for EIWH mini VED plus

Page 1: ... PLQL 9 VHULHV 9 3 1 9 1 7R XVHUV SURIHVVLRQDOV 2SHUDWLQJ DQG LQVWDOODWLRQ LQVWUXFWLRQV 2SHUDWLQJ DQG LQVWDOODWLRQ LQVWUXFWLRQV ...

Page 2: ...ructions 5 2 3 Appliance type 5 3 Product description 5 3 1 Main components 5 3 2 Product features 5 4 Installation 6 4 1 Packing list 6 4 2 Installation method 6 4 3 Technical parameters 7 4 4 Special points related to installation 8 5 Water heater use 8 5 1 Usage of water heater 8 6 Water heater maintenance 8 7 Troubleshooting 9 8 Recycling and disposal 10 9 Guarantee and customer service 10 9 1...

Page 3: ... Only persons from professional company who are sufficiently qualified are allowed to conduct installation commissioning maintenance and repairing of Vaillant EIWH mini VED plus pro It is only allowed to install Vaillant EIWHmini VED plus pro according to the instructions When the appliance is frozen or suspected to be frozen don t switch on the appliance until it is thawed Please check if the ele...

Page 4: ...miniVED plus pro is only used to heat domestic water The domestic water shall comply with national domestic water quality requirement otherwise the appliance may rust If you have any doubts about the water quality please consult the professional Risk of freezing If EIWH mini VED plus pro is kept in non heated area for a long time the water inside the appliance and pipe may freeze in winter Ensure ...

Page 5: ...ation work is finished 3 Product description 3 1 Main components 3 1 1 miniVED plus series VED E 6 1 P IN Fig 3 1 miniVED plus series main components Remark 3 1 2 miniVED pro series VED E 6 1 B IN Fig 3 2 mini VED pro series main components Reamrk 3 2 Product features 3 2 1 miniVED plus series Temperature control built in constant temperature mode default temperature is 38 The water heater include...

Page 6: ...sition of water heater Confirm water heater installation position according to water connection and electrical connections The installation position of the water heater is not more than 50mm from the power cord connection and not more than 50mm from the cold water outlet Use the hanging bracket fixing it to the wall with screws or directly fix the water heater to the wall with screws Fig 4 1 Water...

Page 7: ... controller 2 Heating body 3 Control panel 4 Display board 3 T cock 4 Cold water nozzle 5 Temperature sensor 6 Flow sensor 7 Water resistence detection 1 Temperature controller 2 Heating body 3 Control panel 4 Temperature sensor 5 Flow sensor 6 Water resisitence detection QOHW 2XWOHW Product type VED E 6 1 P IN VED E 6 1 B IN Rated voltage V Rated frequency Hz 220 50 220 50 Rated power kW 5 5 5 5 ...

Page 8: ... there is no water leakage at each joints can the water heater be turned on Starting up Close the air break switch only for the first time use after installation adjust the water mixing tap to the appropriate flow miniVED plus series Press the ON OFF button the display is bright and enter the instant heating mode The display shows the current setting temperature miniVED pro series Turn on the wate...

Page 9: ...E1 Outlet water temperature sensors short circuit or open circuit Check outlet water temperature sensor by a professional E2 Inlet water temperature sensor short circuit or open circuit Check the inlet water temperature sensor by a professional E5 Overheating sensor short circuit or open circuit Check by a professional E7 1 Medium detection short circuit or open circuit 2 Water resistance too high...

Page 10: ...electronic appliances If the product contains batteries that are marked with this symbol these batteries may contain substances that are hazardous to human health and the environment In this case dispose of the batteries at a collection point for batteries 9 Guarantee and customer service 9 1 Guarantee For information on the manufacturer s guarantee you can write to the contact address that is pro...

Page 11: ......

Page 12: ...ce Building Bhandarkar Road Lane 11 Deccan Pune 411 004 TEL 91 9619506391 cs aquagreensolutions in These instructions or parts thereof are protected by copyright and may be reproduced or distributed only with the manufacturer s written consent ...