background image

4

Operating instructions ecoTEC pro 0020129673_00 

a

Safety

a

2

2 Safety

2.1 

Safety and warning information

 

>

When operating your boiler, take account of the general 
safety instructions and the warning notes that appear 
before each action.

2.1.1 

Classification of warnings

The warning notes are classified in accordance with the 
severity of the possible danger using the following warning 
signs and signal words:

Warning signs

Signal 
word

Explanation

a

Danger!

Immediate danger to life or 
risk of
severe personal injury

e

Danger!

Risk of death from electric 
shock

a

Warning!

Risk of minor personal 
injury

b

Caution!

Risk of material or environ-
mental damage

2.1  Meaning of warning signs and signal words

2.1.2  Structure of warnings

Warning signs are identified by an upper and lower separat-
ing line and are laid out according to the following basic 
principle:

a

 Signal 

word!

Type and source of danger!

Explanation of the type and source of dan-
ger

 

>

Measures for averting the danger

2.2  

Intended use

The Vaillant ecoTEC pro boilers are state-of-the-art appli-
ances which have been constructed in accordance with rec-
ognised safety regulations. Nevertheless, there is still a risk 
of injury or death to the operator or others or of damage to 
the boiler and other property in the event of improper use 
or use for which it is not intended.
This boiler is not intended for use by persons (including 
children) having limited physical, sensory or mental capaci-
ties or who have inadequate experience and/or knowledge, 
unless supervised by a person responsible for their safety 
or who has been given instructions from them as to how to 
operate the boiler.
Children must be supervised to ensure that they do not 
play with the boiler. 
The boiler is intended as a heater for closed hot water/cen-
tral heating installations and for  hot water generation. 
The use of the ecoTEC pro in vehicles, such as mobile 
homes and caravans, is not classed as intended use. Units 
that are not classed as vehicles are those that are installed 
in a fixed and permanent location and that do not have any 
wheels (fixed installation).
Any other use, or use beyond that specified, shall be con-
sidered as improper use. Any direct commercial or indus-
trial use is also deemed to be improper.
The manufacturer or supplier is not liable for any damage 
resulting from such use. The user alone bears the risk. 
Intended use includes the following:

 

– observing the included operating, installation and main-

tenance instructions for the Vaillant product and any 
other parts and components of the system

 

– installing and fitting the appliance in accordance with the 

boiler and system approval

 

– complying with all of the inspection and maintenance 

conditions listed in the instructions.

Caution!

Any misuse is forbidden.

Summary of Contents for ecoTEC pro

Page 1: ...Operating instructions For the operator GB IE Operating instructions ecoTEC pro Gas fired wall hung high efficiency boiler...

Page 2: ...flow temperature 13 5 2 1 Setting the heating flow temperature without a controller connected 13 5 2 2 Using a controller to set the heating flow temperature 13 5 3 Domestic hot water generation 13 5...

Page 3: ...or sell the house pass on the documents to the relevant person as well 1 2 Symbols used The symbols used in the text are explained below Symbols for identifying dangers are also used in these operati...

Page 4: ...of improper use or use for which it is not intended This boiler is not intended for use by persons including children having limited physical sensory or mental capaci ties or who have inadequate expe...

Page 5: ...itch the boiler OFF Inform a heating specialist company Explosives and highly flammable substances The risk of explosion arises from the flammable mixture of gas and air Take note of the following Do...

Page 6: ...flue system to the entire condensate drain system to the expansion relief valve or the drain line and constructional conditions that could affect the opera tional reliability of the boiler Cupboard I...

Page 7: ...The hot water pumped into the heating cir cuit exits the boiler at a specific heating flow temperature emits its heat into the rooms and flows back into the boiler once cooled to return temperature T...

Page 8: ...iler on or if you press a button for the DIA system when it is switched on At first pressing this button does not trig ger any other function The light automatically switches off after one minute if y...

Page 9: ...ng time is active This function is used to prevent frequent on off operations and therefore contributes to prolonging the life of your boiler The symbol also appears if the boiler is in a waiting peri...

Page 10: ...hed on by the first press of the button In this case to trigger the button func tion you must press the button again You can switch back to the basic display by pressing the left hand selection button...

Page 11: ...5 1 2 Switching on the boiler b Caution Risk of damage caused by frost Frost protection and monitoring devices are only active while the boiler is connected up to the power supply and your boiler is s...

Page 12: ...into operation again As soon as the system has been topped up with sufficient water the message disappears automatically after approx 20 sec onds If the pressure drops frequently the reason for the l...

Page 13: ...e by pressing the right hand selection button The heating flow temperature is factory set for tempera tures up to 75 C If higher or lower values can be set on your boiler this means that your approved...

Page 14: ...vating deactivating Comfort mode Comfort mode immediately supplies you with hot water at the required temperature without you having to wait for the water to heat up To do this the plate type heat exc...

Page 15: ...n at the on off switch Only switch the boiler on and off in nor mal mode using the controller Make sure that the boiler cannot become damaged by frost 50 1 2 5 9 Switching off the boiler Press the on...

Page 16: ...ing system and the boiler from frost when they are switched off for a very long time is to drain them You must ensure that the heating installa tion and boiler are completely drained All the cold and...

Page 17: ...when doors between heated and unheated partially heated rooms are left open Thermostatic radiator valves and weather compen sators or room thermostats Thermostatic valves on all radiators maintain th...

Page 18: ...lls considerably For example taking a shower instead of a bath While about 150 litres of water are required for a bath a modern shower equipped with water saving fittings only requires a third of this...

Page 19: ...esman or Vaillant Service Solutions 0870 6060 777 to complete such work 7 1 Reading fault messages F 75 7 1 Fault display Fault messages have priority over all other displays If a fault develops in th...

Page 20: ...ing installation too low Top up the heating system with water Section 5 1 4 Air in the heating installation Purge the radiators If the problem occurs again Inform the competent person Ignition malfunc...

Page 21: ...an F 28 1 2 7 3 Resetting the boiler If the burner fails to ignite after five attempts the boiler will not operate and switches to Fault This is indicated by the fault code F 28 Failure during start u...

Page 22: ...s Status code Meaning Displays in heating mode S 00 Heating no heat requirement S 02 Heating mode Pump flow S 03 Heating mode Ignition S 04 Heating mode Burner on S 06 Heating mode fan slow down S 07...

Page 23: ...ss and safety reliability and a long working life require inspections and maintenance work to be carried out annually on the boiler by your approved skilled tradesman Regular servicing ensures maximum...

Page 24: ...Disposing of the boiler Do not dispose of your Vaillant ecoTEC pro boiler or any of its accessories in the household waste Make sure the old unit and any accessories are disposed of properly Observe...

Page 25: ...turn to Vaillant within 30 days of instal lation Your details will then be automatically registered within the Vaillant scheme Note No receipt will be issued Immediate help If your Vaillant boiler dev...

Page 26: ...on between the heating technology components e g controller boiler vrnetDIALOG Frost protection The frost protection function protects your heating system and dwelling from frost damage If the heating...

Page 27: ...Filling 12 Filling pressure 12 Filling the heating installation 12 Flue gas 5 Flue gas smell 5 Frost Activating the frost protection function 15 Draining the heating installation 16 Protecting the hea...

Page 28: ...Index 28 Operating instructions ecoTEC pro 0020129673_00 T Temperature Setting the hot water temperature 13 14 Troubleshooting 19 V Vaillant customer service 25 W Water shortage 20...

Page 29: ......

Page 30: ......

Page 31: ...ing the heating temperature switching on Heating mode Section 5 2 1 50 50 48 Right hand selection but ton button for selecting the temperature Confirm 3 Setting the hot water temperature Section 5 3 1...

Page 32: ...0020129673_00 GBIE 092011 Subject to change Manufacturer Supplier...