background image

Operation

Operating instructions ecoTEC pro 0020129673_00 

15

5

5.5  

Switching off Heating mode ( summer mode)

off

5.8  Switching off Heating mode (summer mode)

You can switch off the heating mode in summer without 
switching off the  domestic hot water supply.

 

>

Press the right-hand selection button 

 

(" ").

The value of the heating flow temperature appears in the 
display. 

 

>

Use the minus button 

 to set the domestic hot 

water flow temperature to "Off".

 

>

Confirm the change by pressing the right-hand selection 
button 

 (“ ”).

Heating mode is switched off. The   symbol appears on the 
display.

To switch Heating mode on again:

 

>

Use the plus button 

 to set your required 

heating flow temperature.

 

>

Confirm the change by pressing the right-hand selection 
button 

 (“ ”).

5.6  

 Temporarily shutting down the boiler

b

 Caution!

Risk of damage caused by frost.

Anti-freeze and monitoring devices are only 
active while the boiler is connected up to 
the power mains and the on/off switch is 
on.

 

>

Do not isolate the boiler from the power 
mains.

 

>

Leave your boiler switched on at the on/
off switch.

 

>

Only switch the boiler on and off in nor-
mal mode using the controller.

 

>

Make sure that the boiler cannot become 
damaged by frost.

50

1

2

5.9  Switching off the boiler

 

>

Press the on/off switch (

1

) to switch the boiler off.

If the boiler is switched off, the  display (

2

) turns off.

i

  If the boiler is going to be unused for longer 

periods (e.g. holiday), you should also close the 
gas isolator cock and the cold water stop valve, 
but only if there is no risk of frost.

5.7  

 Protecting the heating system against frost

5.7.1  

 Activating the frost protection function

Your Vaillant ecoTEC is fitted with a frost protection func-
tion for each boiler:
If the heating flow temperature falls below 5 °C when the 
on/off switch is on, the boiler comes into operation and 
heats the heat generation circuit to approx. 30 °C on both 
the heating side and the domestic hot water side (if availa-
ble).

b

 Caution!

Risk of damage caused by frost.

The frost protection function cannot guar-
antee flow through the entire heating 
installation, which means that parts of the 
heating installation may freeze and become 
damaged.

 

>

Make sure that the boiler remains on 
whilst you are away.

 

>

Make sure that the rooms are heated suf-
ficiently.

Summary of Contents for ecoTEC pro

Page 1: ...Operating instructions For the operator GB IE Operating instructions ecoTEC pro Gas fired wall hung high efficiency boiler...

Page 2: ...flow temperature 13 5 2 1 Setting the heating flow temperature without a controller connected 13 5 2 2 Using a controller to set the heating flow temperature 13 5 3 Domestic hot water generation 13 5...

Page 3: ...or sell the house pass on the documents to the relevant person as well 1 2 Symbols used The symbols used in the text are explained below Symbols for identifying dangers are also used in these operati...

Page 4: ...of improper use or use for which it is not intended This boiler is not intended for use by persons including children having limited physical sensory or mental capaci ties or who have inadequate expe...

Page 5: ...itch the boiler OFF Inform a heating specialist company Explosives and highly flammable substances The risk of explosion arises from the flammable mixture of gas and air Take note of the following Do...

Page 6: ...flue system to the entire condensate drain system to the expansion relief valve or the drain line and constructional conditions that could affect the opera tional reliability of the boiler Cupboard I...

Page 7: ...The hot water pumped into the heating cir cuit exits the boiler at a specific heating flow temperature emits its heat into the rooms and flows back into the boiler once cooled to return temperature T...

Page 8: ...iler on or if you press a button for the DIA system when it is switched on At first pressing this button does not trig ger any other function The light automatically switches off after one minute if y...

Page 9: ...ng time is active This function is used to prevent frequent on off operations and therefore contributes to prolonging the life of your boiler The symbol also appears if the boiler is in a waiting peri...

Page 10: ...hed on by the first press of the button In this case to trigger the button func tion you must press the button again You can switch back to the basic display by pressing the left hand selection button...

Page 11: ...5 1 2 Switching on the boiler b Caution Risk of damage caused by frost Frost protection and monitoring devices are only active while the boiler is connected up to the power supply and your boiler is s...

Page 12: ...into operation again As soon as the system has been topped up with sufficient water the message disappears automatically after approx 20 sec onds If the pressure drops frequently the reason for the l...

Page 13: ...e by pressing the right hand selection button The heating flow temperature is factory set for tempera tures up to 75 C If higher or lower values can be set on your boiler this means that your approved...

Page 14: ...vating deactivating Comfort mode Comfort mode immediately supplies you with hot water at the required temperature without you having to wait for the water to heat up To do this the plate type heat exc...

Page 15: ...n at the on off switch Only switch the boiler on and off in nor mal mode using the controller Make sure that the boiler cannot become damaged by frost 50 1 2 5 9 Switching off the boiler Press the on...

Page 16: ...ing system and the boiler from frost when they are switched off for a very long time is to drain them You must ensure that the heating installa tion and boiler are completely drained All the cold and...

Page 17: ...when doors between heated and unheated partially heated rooms are left open Thermostatic radiator valves and weather compen sators or room thermostats Thermostatic valves on all radiators maintain th...

Page 18: ...lls considerably For example taking a shower instead of a bath While about 150 litres of water are required for a bath a modern shower equipped with water saving fittings only requires a third of this...

Page 19: ...esman or Vaillant Service Solutions 0870 6060 777 to complete such work 7 1 Reading fault messages F 75 7 1 Fault display Fault messages have priority over all other displays If a fault develops in th...

Page 20: ...ing installation too low Top up the heating system with water Section 5 1 4 Air in the heating installation Purge the radiators If the problem occurs again Inform the competent person Ignition malfunc...

Page 21: ...an F 28 1 2 7 3 Resetting the boiler If the burner fails to ignite after five attempts the boiler will not operate and switches to Fault This is indicated by the fault code F 28 Failure during start u...

Page 22: ...s Status code Meaning Displays in heating mode S 00 Heating no heat requirement S 02 Heating mode Pump flow S 03 Heating mode Ignition S 04 Heating mode Burner on S 06 Heating mode fan slow down S 07...

Page 23: ...ss and safety reliability and a long working life require inspections and maintenance work to be carried out annually on the boiler by your approved skilled tradesman Regular servicing ensures maximum...

Page 24: ...Disposing of the boiler Do not dispose of your Vaillant ecoTEC pro boiler or any of its accessories in the household waste Make sure the old unit and any accessories are disposed of properly Observe...

Page 25: ...turn to Vaillant within 30 days of instal lation Your details will then be automatically registered within the Vaillant scheme Note No receipt will be issued Immediate help If your Vaillant boiler dev...

Page 26: ...on between the heating technology components e g controller boiler vrnetDIALOG Frost protection The frost protection function protects your heating system and dwelling from frost damage If the heating...

Page 27: ...Filling 12 Filling pressure 12 Filling the heating installation 12 Flue gas 5 Flue gas smell 5 Frost Activating the frost protection function 15 Draining the heating installation 16 Protecting the hea...

Page 28: ...Index 28 Operating instructions ecoTEC pro 0020129673_00 T Temperature Setting the hot water temperature 13 14 Troubleshooting 19 V Vaillant customer service 25 W Water shortage 20...

Page 29: ......

Page 30: ......

Page 31: ...ing the heating temperature switching on Heating mode Section 5 2 1 50 50 48 Right hand selection but ton button for selecting the temperature Confirm 3 Setting the hot water temperature Section 5 3 1...

Page 32: ...0020129673_00 GBIE 092011 Subject to change Manufacturer Supplier...

Reviews: