Fig. 4.9 Connection wiring
X20
X2
-
+
BUS
24V
230V
7
8
9
L
N
3
4
5
X40
X41
X31
Caution:
Do not connect
supply voltage!
Risk of damage
to electronics!
Room thermostat 24V:
Connection 7, 8 and 9
No bi-directional
interface (analogue only)
Mains supply: 230V / 50Hz
Room thermostat 230V / 50Hz
(remove bridge on connection)
Heating pump
2A fuse, slow
Igniter
Connection: 230V
Supply for accessory module
eBUS accessory connection
Burner cable harness
Accessory module connection
Diagnosis via eBUS
vrnet DIALOG
outer probe
ext. flow or return probe
Hydraulic cable harness
Connection for external
eBUS controller
ext. flow or return probe
X12
4.4.3 Electrical board layout
Boiler installation sequence 4