Appendix
36
Installation and maintenance instructions ecoTEC exclusive 0020189875_01
Code
Parameter
Values
Unit
Increment, select, explanation
Default
setting
Own
setting
Min.
Max.
D.058
Solar post-heating
0
3
–
Only products with integrated do-
mestic hot water generation
0 = Solar post-heating deactivated
3 = Domestic hot water activated
(min. target value 60 °C)
0
D.060
Number of safety therm.
shut-downs
Current value
–
Number of safety cut-out switch-off
sequences
–
Not ad-
justable
D.061
No. of shut-downs in ign.
flame controller
Current value
–
–
–
Not ad-
justable
D.064
Avg. ignition time
Current value
s
–
–
Not ad-
justable
D.065
Max. ignition time
Current value
s
–
–
Not ad-
justable
D.067
Remaining anti-cycl. time
for heating
Current value
min
–
–
Not ad-
justable
D.068
Number of first start at-
tempts
Current value
–
Unsuccessful ignitions at 1st at-
tempt
–
Not ad-
justable
D.069
Number of second start
attempts
Current value
–
Unsuccessful ignitions at 2nd at-
tempt
–
Not ad-
justable
D.070
3-way valve operation
0
2
–
0 = Normal operating mode
1 = Mid-position (parallel operation)
2 = Permanent heating position
0
D.071
Max. heating target flow
temp.
40
80
°C
Target value maximum heating flow
temperature
1
75
D.072
Pump overrun after cylin-
der charging
0
10
min
Internal pump
1
2
D.073
Offset setting for comfort
mode
−
15
5
K
Only products with integrated do-
mestic hot water generation
1
0
D.074
Anti-legionella funct. with
integrated cyl.
0
1
–
0: Off
1: On
1
D.075
Max. cylinder charging
time
20
90
min
Max. charging time for domestic
hot water cylinder without inde-
pendent control system
1
45
D.076
Device Specific Number
Current value
–
(Device specific number = DSN)
–
Not ad-
justable
D.077
DHW partial load
Output-range-
specific
kW
Adjustable cylinder charging output
100 %
D.078
DHW max. flow temperat-
ure
55
80
°C
Limit on cylinder charging temper-
ature
1
Note
The chosen value must be at least
15 K above the cylinder target
value.
75
D.080
Heating operating hours
Current value
h
–
–
Not ad-
justable
D.081
DHW operating hours
Current value
h
–
–
Not ad-
justable
D.082
Heating burner starts
Current value
–
–
–
Not ad-
justable
D.083
DHW burner starts
Current value
–
–
–
Not ad-
justable
D.084
Maintenance in
„
– – –
”
3000
h
Number of hours until the next
maintenance
1
"
– – –
" = Deactivated
–