Status code
Parameter
Meaning
S.25
DHW mode: Pump/fan overrun
DHW mode: Pump/fan overrun
S.26
DHW mode: Fan overrun
DHW mode: Fan overrun
S.27
DHW mode: Pump overrun
DHW mode: Pump overrun
S.28
DHW anti-cycling time
Domestic hot water burner anti-cycling time
S.29
DHW mode: Measuring program
DHW mode: Measuring programme
Others
S.30
No heat demand: Controller
Room thermostat (RT) is blocking heating mode
S.31
No heat demand: Summer mode
Summer mode active or no heat requirement from eBUS
control
S.32
Waiting time deviation: Fan speed
Waiting period because of fan speed deviation
S.33
Waiting time: Air monitor
Waiting period: Air pressure sensor/switch reports that
the pressure signal is too low
S.34
Heating mode: Frost protection
Frost protection mode active
S.36
Target value for ext. controller lower than 20 °C
Reference setting for continuous controller 7-8-9 or
eBUS controller is < 20°C and blocks the heating mode
S.37
Waiting time: Deviation in fan speed
Waiting period: Fan failure in operation
S.39
Contact thermostat triggered
"Burner off contact" has responded (e.g. surface-moun-
ted thermostat or condensate pump)
S.40
Comfort protection active
Comfort protection mode is active: Product running with
limited heating comfort
S.41
Water pressure too high
Water pressure > 2.8 bar
S.42
Flue non-return flap closed
Flue non-return flap response blocks burner operation
(only in conjunction with accessory VR40) or condensate
pump defective; heat requirement is blocked
S.46
Comfort protection: Minimum load, loss of flame
Comfort protection mode, flame loss at minimum load
S.53
Waiting time: Water shortage
Product is within the waiting period of the modulation
block/operating block function as a result of water defi-
ciency (flow/return spread too large)
S.54
Waiting time: Water shortage
Product is within the waiting period of the operating
blocking function as a result of water deficiency
(temperature gradient)
S.55
Waiting time: CO sensor
Waiting period: CO sensor
S.56
Waiting time: CO limit value exceedance
Waiting period: CO limit value exceedance
S.57
Waiting time: Measuring program
Calibration unsuccessful. Waiting period, comfort protec-
tion mode
S.58
Burner modulation limitation
Modulation limitation due to noise/wind
S.59
Waiting time: Water circulation vol.
Minimum circulation water volume
S.76
Service message: Check water pressure
System pressure too low. Top up water.
S.86
Service message: Check vortex sensor
Service message: Check vortex sensor
S.88
Purging programme is running
Purging programme is running
S.92
Water circulation volume self-test
Water circulation volume self-test
S.93
Flue gas measurement not possible
Flue gas analysis not possible because not all measur-
ing programmes have yet run
S.96
Return temperature sensor self-test
Return sensor test running, heating demands are
blocked.
S.97
Water pressure sensor self-test
Water pressure sensor test running, heating demands
are blocked.
S.98
Flow/return temperature sensor self-test
Flow/return sensor test running, heating demands are
blocked.
S.99
Vaillant self-test
Self-test