Vaillant ecoCRAFT VKK GB 806/2-E-H Operating Manual Download Page 6

6

Operating manual

 ecoCRAFT 

Do not cover regulators

Do not cover your regulators with furniture, drapes or 
similar objects. The room air must circulate unhindered. 
Covered thermostat valves can be equipped with remote 
sensors and thus still work.

Appropriate hot water temperature

The warm water should only be heated up to the extent 
that is necessary for use. Any further heating results in 
unnecessary power consumption and hot water 
temperatures of more than 60 °C also lead to increased 
lime scale production.

Energy-conscious use of water

Energy-conscious use of water can reduce your bills 
considerably.
For example, taking a shower instead of a bath: Whereas 
about 150 litres of water are required for a bath, a 
modern shower equipped with water saving fittings only 
requires a third of this water quantity.
By the way, a dripping water tap wastes up to 2000 
litres of water and a leaking toilet flush up to 4000 litres 
of water each year. On the other hand, a new seal only 
costs a few cents.

Run circulation pumps only if needed

Hot water piped systems are often fitted with so-called 
circulation pumps. These provide continuous re-
circulation of hot water in the piping system so that hot 
water is immediately available, even at drawing-off 
points which are located far away.
These circulation pumps can also be used with the 
Vaillant ecoCRAFT. There is no doubt that they provide 
increased comfort for hot water heating. Please bear in 
mind, however, that these pumps consume electricity. 
And circulating hot water that is not used cools off when 
passing through pipes and then needs to be reheated. 
Therefore, circulation pumps are to be operated only 
when hot water is actually needed for the household.
Individual time programmes can be set using timers 
which most circulation pumps have fitted to them or 
with which they can be retro-fitted. Weather 
compensators often have ancillary functions for 
controlling circulation pump timings. Ask your heating 
engineer about this.

Ventilating residential spaces

During the heating period, open windows only for 
ventilation and not for temperature regulation. A brief 
impact-ventilation is more effective and energy-saving 
than windows that are kept open for a long time. We 
recommend that the windows be opened fully for a short 
period. During ventilation, close all thermostat valves in 
the room or set the room regulator to minimum 
temperature. In this way, there will be adequate 
ventilation without unnecessary cooling and energy loss 
(e.g. by the heating switching on during the ventilation 
procedure).

4 Operation

4.1 Checks 

before 

start-up

4.1.1 Opening 

the 

shut-off 

valves

 Note!

The shut-off valves are not included in the 
scope of supply of your unit. They are fitted by 
your heating engineer in the installation. He 
should show you the location and how to 
operate these components.

4.1.2 Checking water level

•  Check the water level (fill pressure) of the installation 

at the pressure gauge external to the boiler.

Your heating engineer has shown you the location of the 
pressure gauge. It is not integrated into your unit. For 
the heating system to operate properly, the indicator on 
the pressure gauge should be at approx. 3 bar when the 
system is cold. If it is less than 0.8 bar, then water 
should be added.
There is a water pressure switch integrated in the unit 
which prevents the unit from starting up if the system 
pressure < 0.2 bar. This is shown in the display as 

E26

At water pressures > 0.8 bar the fault display disappears.
If the heating system extends over several storeys, the 
system may require a higher filling pressure. Ask your 
engineer for details.

3 Notes on the installation and operation
4 Operation

Summary of Contents for ecoCRAFT VKK GB 806/2-E-H

Page 1: ...For the owner VKK GB 806 2 E H VKK GB 1206 2 E H VKK GB 1606 2 E H VKK GB 2006 2 E H VKK GB 2406 2 E H VKK GB 2806 2 E H Operating manual ecoCRAFT Modular Gas Condensing Boiler GB...

Page 2: ...e accept no liability for any damage caused by failure to observe these instructions Other applicable documents All operating manuals of structural parts and components of the installation must be obs...

Page 3: ...rations to structural elements in the vicinity of the appliance which might affect its operational safety For example Keep all openings for air and flue gas free Make sure for example that any tempora...

Page 4: ...ecoCRAFT units are state of the art appliances which have been constructed in accordance with recognised safety regulations Nevertheless there is still a risk of death or serious injury to the user o...

Page 5: ...to summer mode The heating mode is then shut off however the device or the plant remains ready for operation for water heating Uniform heating Often in an apartment with central heating only one room...

Page 6: ...mes can be set using timers which most circulation pumps have fitted to them or with which they can be retro fitted Weather compensators often have ancillary functions for controlling circulation pump...

Page 7: ...ult resolution see Chapter 5 1 9 Button for switching the unit on and off 4 3 Switching the unit on and off 1 Fig 4 2 Switching the unit on and off Caution The mains switch may only be actuated if the...

Page 8: ...operational condition of your unit The operation codes 1 2 and 5 appear at the start of each individual module The number of the individual module is preset on the operational display The following di...

Page 9: ...ory setting max Call ups and settings Setting Display Store set value with OK Factorysettingmaynot bechanged Operation mode ParameterNo ParameterNo ParameterNo Factorysettingmaynot bechanged Hotwater...

Page 10: ...C in the parameter level under point 3 Caution None of the other settings in the parameter level can be changed to avoid malfunctions 4 6 Diagnosis mode In the diagnosis mode you can have the individu...

Page 11: ...fault resolution button 1 on the operating field The faults on the boiler can be resolved as follows First reset the relevant module by pushing the corresponding red module reset button 1 on the opera...

Page 12: ...itch integrated in the unit which prevents the unit from starting up if the system pressure 0 2 bar This is shown in the display as E26 At water pressures 0 8 bar the fault display disappears If the h...

Page 13: ...peration of your boiler it is recommended that regular servicing is carried out by your service provider Vaillant Applied System Sales Vaillant Ltd Unit D1 Lowfields Business Park Elland West Yorkshir...