Notes on the documentation 2

0020149575_01 ecoCRAFT exclusive Operating instructions

7

2 Notes on the

documentation

2.1 Observing other applicable

documents

You must observe all operating instruc-
tions enclosed with the system compon-
ents.

2.2 Storing documents

Keep this manual and all other applic-
able documents safe for future use.

2.3 Validity of the instructions

These instructions apply only to:

Product

Article numbers

VKK GB 806/3-E
R1

0010014388

VKK GB 1206/3-
E R1

0010014389

VKK GB 1606/3-
E R1

0010014390

VKK GB 2006/3-
E R1

0010014391

VKK GB 2406/3-
E R1

0010014392

VKK GB 2806/3-
E R1

0010014393

3 Product description

3.1 Identification plate

The identification plate is mounted on the
rear of the product. The identification plate
contains the following information:

Serial number

Type designation

Designation of the type approval

Technical data

CE label

The seventh to sixteenth digits of the serial
number on the identification plate form the
article number.

3.2 Opening the front flap

1

2

Open the front flap by lifting the silver
handle bar

(1)

.

The front flap

(2)

automatically swiv-

els downwards and the control panel
becomes accessible.

3.3 Overview of the operator

control elements

1

Display

2

i

button

3

Control (access-
ory)

4

Main switch

5

+

button

6

button

7

Fault clearance

key

8

Heating flow
temperature
rotary knob

9

Rotary knob for
the cylinder tem-
perature in the
domestic hot wa-
ter cylinder

The display shows the current heating flow
temperature, the system pressure of the

Summary of Contents for ecoCRAFT exclusive

Page 1: ...ing instructions ecoCRAFT exclusive VKK GB 6 3 E R1 GB IE Operating instructions Publisher Manufacturer Vaillant GmbH Berghauser Str 40 D 42859 Remscheid Tel 49 21 91 18 0 Fax 49 21 91 18 2810 info vaillant de www vaillant de ...

Page 2: ...duct 10 4 2 Switching off the product s functions 14 4 3 Carrying out the flue gas analysis 15 5 Troubleshooting 15 5 1 Detecting and rectifying faults 15 5 2 Checking the product status 16 5 3 Status code meanings 16 5 4 F 22 Risk of dry fire 16 5 5 F 28 No ignition on start up 16 5 6 F 29 Flame goes out during operation 17 5 7 F 32 Risk of flue gas exit 17 6 Care and maintenance 17 6 1 Maintenan...

Page 3: ...d heat ing installations and for hot wa ter generation Intended use includes the fol lowing observance of the operating instructions included for the product and any other system components compliance with all inspection and maintenance conditions listed in the instructions This product can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabili...

Page 4: ...trical switches mains plugs door bells telephones or other communication systems in the building If it is safe to do so close the emergency control valve or the main isolator If possible close the gas isol ator cock on the product Warn other occupants in the building by yelling or banging on doors or walls Leave the building immedi ately and ensure that others do not enter the building Notify the ...

Page 5: ...fi cient supply of combustion air 1 3 7 Risk of corrosion damage due to unsuitable combustion and room air Sprays solvents chlorinated cleaning agents paint adhes ives ammonia compounds dust or similar substances may lead to corrosion on the product and in the air flue pipe Ensure that the supply of combustion air is always free of fluorine chlorine sulphur dust etc Ensure that no chemical sub sta...

Page 6: ...ating in stallation 1 3 10 Risk of injury and material damage due to maintenance and repairs carried out incorrectly or not carried out at all Never attempt to carry out maintenance work or repairs on your product yourself Faults and damage should be immediately rectified by a competent person Adhere to the maintenance intervals specified ...

Page 7: ...he identification plate is mounted on the rear of the product The identification plate contains the following information Serial number Type designation Designation of the type approval Technical data CE label The seventh to sixteenth digits of the serial number on the identification plate form the article number 3 2 Opening the front flap 1 2 Open the front flap by lifting the silver handle bar 1...

Page 8: ...to reset the product in the case of certain faults The heating flow temperature rotary knob is used to set the heating flow temperature if no controller is connected If a controller is connected the heating flow temperature rotary knob should be turned clockwise as far as it will go The cylinder temperature rotary knob is used to set the cylinder temperature if a domestic hot water cylinder is con...

Page 9: ... anti cycling time is active Sym bol Meaning Explanation Hot water gener ation Symbol per manently vis ible Charging mode for the domestic hot water cylinder is enabled by the control and floor standing boiler control system Symbol flashes Do mestic hot water cylin der is being heated Heating pump operating Solenoid valve is actuated Gas supply to the burner is open Current energy demand Display o...

Page 10: ...hmark Checklist will be required in the event of any warranty 3 5 CE label The CE label shows that the products comply with the basic requirements of the applicable directives as stated on the iden tification plate The declaration of conformity can be viewed at the manufacturer s site 4 Operation 4 1 Starting up the product 4 1 1 Opening the isolator devices 1 Ask the competent person who in stall...

Page 11: ...trol is present block the heating and cylinder charging mode by turning the dial to the anti clockwise end stop 4 1 4 Checking the system pressure 1 Check the heating installation s filling pressure at regular intervals Briefly press the 1 button The display will show the filling pres sure for approximately 5 seconds The filling pressure must lie between 1 0 and 2 0 bar when the heating in stallat...

Page 12: ...ly Note If the heating installation ex tends over several floors a higher system pressure for the heating installation may be ne cessary Ask your competent person for details 4 1 5 Filling the heating installation Caution Risk of material damage due to heating water that is ex tremely calciferous or corros ive or contaminated by chem icals Unsuitable tap water damages the seals and diaphragms bloc...

Page 13: ...g Outside tem perature Fully left Frost pro tection Anti clock wise but not at the end stop Transition Time Approx 10 20 Centre Moderate cold Approx 0 10 Clockwise Extreme cold Below 0 After turning the rotary knob for the heating flow temperature the display shows the set target flow temper ature 2 After three seconds this display goes out and the default display reappears current heating flow te...

Page 14: ...ing flow temperature Note The maximum cylinder tem perature is set in the factory at 65 C This can be defined by the competent person to be between 50 C and 70 C 4 2 Switching off the product s functions 4 2 1 Switching off cylinder charging mode using the VRC 630 VRS 620 VRC 700 control 1 Leave the rotary knob for the cylinder temperature at the clockwise end stop 2 Switch the cylinder circuit to...

Page 15: ...e same time Shown in the display S Fh Heat ing chimney sweep operation S Fb Domestic hot water chimney sweep operation The product now works at maximum load for 15 minutes If you do not press any buttons for 15 minutes or if a flow temperature of 85 C is reached the chimney sweep func tion is automatically switched off 2 Take the measurements at the earliest after three minutes of the product oper...

Page 16: ... 4 F 22 Risk of dry fire As soon as the system pressure falls below 0 06 MPa 0 6 bar the pressure display flashes in the display along with the current water pressure As soon as you have added sufficient water the cur rent flow temperature is displayed again If the pressure falls below 0 03 MPa 0 3 bar the product switches off Fault message F 22 appears in the display Fill the heating installation...

Page 17: ... out by a competent person is a prerequis ite for ensuring that the product is perman ently ready and safe for operation reliable and has a long working life 6 1 1 Checking the condensate drain pipework and tundish The condensate drain pipework and tun dish must always be penetrable Regularly check the condensate drain pipework and tundish for faults and particularly for blockages You must not be ...

Page 18: ...on to explain where the isolators are located and how they are oper ated 7 1 1 Preventing frost damage The product is equipped with a frost pro tection function If the heating flow temperature falls be low 5 C when the main switch is switched on the product starts up and heats the cir culating water on both the heating side and the hot water side if available to ap prox 30 C Caution Risk of materi...

Page 19: ...ed provided that An annual service has been carried out by a competent person approved at the time by the Health and Safety Executive The cost of these services is not included in the guarantee The water flowing through the boiler is maintained with adequate and appropriate inhibitors Any additional guar antee applies only if the boiler and system has been maintained as above If there is no eviden...

Page 20: ...tion malfunction Press the reset button If the problem occurs again In form the competent person Hot water handling mode without any problems heating does not start No heat requirement via the control ler Check the timer programme on the controller and correct if neces sary Check the room temperature and if required correct the target room temperature Controller operating instructions The heating ...

Page 21: ...Appendix 0020149575_01 ecoCRAFT exclusive Operating instructions 21 B Gaskeur ...

Page 22: ......

Page 23: ......

Page 24: ...re DE56 1JT Telephone 0330 100 3461 info vaillant co uk www vaillant co uk These instructions or parts thereof are protected by copyright and may be reproduced or distributed only with the manufacturer s written consent We reserve the right to make technical changes 0020149575_01 ...