6
Installation Instructions
for Control Center VR 65
4.4
Assembling Control Center VR 65
The Control Centre connection terminals are provided
with System ProE plugs. All onsite connections must be
made using these plugs.
Fig. 4.1 Opening the Control Centers
• Press the catch on the upper edge of the box down-
wards using a screw driver.
• Pull the housing cover forwards.
USE
DO NOT
230V~
N L
2
1
NTC
CYL.
CH
DHW
N on
on
off
DHW
on
N
BUS
+
-
2
3
1
4
Fig. 4.2 Assembling the Control Centers
Key
1 Operating
LED
2 Fixing
holes
3 Cable
clamps
4 On/Off
switch
• Mark out the 2 fixing holes (
2
) and drill the holes.
• Select the wall plugs to suit the state of the wall and
screw the housing
tight.
• Wire up the Control Center as shown in the wiring dia-
grams (fig. 5.2 or 5.3).
• Fix all cables using the cable clamps (
3
).
• Finally, press the covering back onto the housing so
that is clicks into place audibly.
5 Electrical
installation
The electrical connection must be done by a suitably
qualified heating engineer who is responsible for com-
plying with the existing standards and guidelines.
Danger!
Risk of death from electric shock through con-
tact with live connections!
Isolate the mains power supply before working
on the unit, and ensure that the power cannot
be accidentally restarted.
Using the mains switch on the VR 65 or on the
heating appliance is not sufficient to isolate all
terminals of the system.
Caution!
In order to avoid damage to the heating appli-
ance or the VR 65 Control Centre, any existing
230 V wiring box installation must be removed
completely.
230 V
VR 65
optional
(VRT 360 or
VRC 400)
Vaillant
ecoTEC
230 V~
eBUS connection
optional
VRC 693 for
VRC 400
Fig. 5.1 Connection of eBUS and mains cable in the system
4 Installation
5 Electrical installation