Installation Instructions 

for Control Center VR 65

4 Installation

The Control Center can be wall-mounted near to the 
DHW cylinder. The hot water and heating programs as 
well as all required parameters are set at the VRT 360 
or VRC 400. All heating circuit connections are made at 
the Control Center using a ProE plug.

4.1 Installation 

overview

Please check the following before installing the VR 65 
Control Center:
-  Read the installation instructions
-  Check the scope of delivery
-  Assemble the VR 65
-  Carry out electrical installation

4.2 

Scope of delivery

Using Table 4.1, check that all the components have been 
delivered with the VR 65.

Pos.

Number

Components

1

1

Control Center VR 65

1

Standard sensor VR 10

3

1

Cable clamps (7 pcs.)

4

1

Bag of screws

Table 4.1  Scope of delivery of the Control Centers VR 65 

4.3 Accessories

timeSWITCH 140

Digital 2-channel timer with daily/weekly program for 
heating and hot water.
The timeSWITCH 140 can be plugged into the Vaillant 
ecoTEC boiler.
There are three individually programmable time win-
dows per day for heating and hot water. The timer can 
be set to run a weekly or a daily program.
By activating the calendar function, an automatic 
summer/winter changeover is activated.

VRT 360

Digital room temperature thermostat with daily/weekly 
program for time and temperature control of heating 
and hot water.
Designed for wall mounting. 
There are three individually programmable time win-
dows per day for heating, hot water and a hot water 
circulation pump. Different target room temperatures 
can be set for each time window.
The thermostat can be set to run a weekly or a daily 
program.
By activating the calendar function, an automatic 
summer/winter changeover is activated.

VRC 400

Digital weather-dependent control with daily/weekly 
program for time and temperature control of heating 
and hot water.
Designed to plug into the Vaillant ecoTEC boiler or for 
wall mounting.

  Set the heating curve to adjust the flow temperature 

to suit the heat requirement of the building. Optimises 
the flow temperature to the prevailing weather condi-
tions.
There are three individually programmable time win-
dows per day for heating, hot water and a hot water 
circulation pump. Different target room temperatures 
can be set for each time window.
The control can be set to run a weekly program or a 
daily program.
By activating the calendar function, an automatic sum-
mer/winter changeover is activated.

 Caution!

Do not use a VRT 360 or VRC 400 in combina-
tion with an additional room temperature ther-
mostat e.g. VRT 30 due to the impact this may 
have on the operation of the VRT 360 or VRC 
400.

Installation 4

Summary of Contents for Control Center VR 65

Page 1: ...For the qualified engineer VR 65 Installation instructions Control Center VR 65 Control Center for storage connection eBUS GB ...

Page 2: ......

Page 3: ...a solution to allow Vaillant low voltage eBUS controls to be used with the traditional 230 V zone valves and DHW storage cylinder in the English market Information about the heat required by the cylinder is forwarded by the Control Center VR 65 to the Vaillant ecoTEC heating appliance The boiler then decides whether a hot water request has to be fulfilled and sends a signal to position the 230 V z...

Page 4: ...tended use includes the observance of the installation manual Note The VR 65 is designed to control one 3 port valve or two 2 port valves Systems requiring more zone valves or a combination of 3 port and 2 port valves are not possible Note The VR 65 requires a 230 V supply The ecoTEC boiler also requires a 230 V supply The eBUS wiring between the two will not provide 230 V from one device to the o...

Page 5: ...ivated VRT 360 Digital room temperature thermostat with daily weekly program for time and temperature control of heating and hot water Designed for wall mounting There are three individually programmable time win dows per day for heating hot water and a hot water circulation pump Different target room temperatures can be set for each time window The thermostat can be set to run a weekly or a daily...

Page 6: ... the cable clamps 3 Finally press the covering back onto the housing so that is clicks into place audibly 5 Electrical installation The electrical connection must be done by a suitably qualified heating engineer who is responsible for com plying with the existing standards and guidelines Danger Risk of death from electric shock through con tact with live connections Isolate the mains power supply ...

Page 7: ... has a mains switch see fig 4 2 to isolate the internal electronics as well as all connected zone valves for the purposes of tests and maintenance When the housing cover has been removed a green LED indicates if the VR 65 is still connected to the mains voltage CYL USE DO NOT 230 V N L M 3 Port EARTH BLUE BROWN or WHITE ORANGE GREY DHW on N CH DHW N on on off BUS 2 1 NTC NTC for use with Vaillant ...

Page 8: ...a mains switch see fig 4 2 to isolate the internal electronics as well as all connected zone valves for the purposes of tests and maintenance When the housing cover has been removed a green LED indicates if the VR 65 is still connected to the mains voltage CYL USE DO NOT 230 V N L CH DHW M M EARTH BLUE BROWN BLUE BROWN 2 Port DHW on N CH DHW N on on off BUS 2 1 NTC EARTH NTC for use with Vaillant ...

Page 9: ...rminal box see 2 fig 5 4 Version B fig 5 5 To remove the cylinder control a release the clips with two screw drivers as shown in fig 5 5 Remove the capillary tubes 3 of the thermostat and the thermal cutout from the dry pocket of the uniSTOR Ensure that the capillary tube of the immersion sensor is not removed Now the NTC can be pushed into the free dry pocket of the cylinder as shown in fig 5 6 T...

Page 10: ...er priority The 3 port valve is in the heating or hot water position depending on the operating mode With 2 port valves either the DHW valve or the CH valve is open both valves are closed on standby x 1 Enable mid position The 3 port valve is in the mid position for simultaneous heating and hot water request or in the heating or hot water position depending on the operating mode With 2 port valves...

Page 11: ...ata Feature Unit VR 65 Operating voltage V 230 Power consumption VA 2 Contact load of output relays max cos ϕ 0 6 A 2 Contact voltage for DHW cylinder thermostat V 230 Operating voltage of temperature sensor NTC V 5 Minimum cross section of the temperature sen sor cables eBUS cables mm2 0 75 Minimum cross section of the power supply cable rigid cable NYM mm2 1 5 Maximum ambient temperature C 70 Ho...

Page 12: ...00 2000 7476_02 GB 11 2005 ...

Reviews: