Flat roof fitting and installation 5
0020077994_02 auroTHERM exclusive Installation manual
47
5.2
Carrying out the installation
5.2.1
Installing racks
Danger!
Risk of death due to falling collectors!
Unsecured collectors may fall from the flat
roof due to the wind and present a danger
to persons.
▶
Perform the following safety precau-
tions according to the installation type.
▶
For direct connection, screw the rack
properly onto the base.
▶
Only use suitable load weights.
▶
Observe the required ballast load of the
load weights.
1.
Determine the required number of racks.
Specifications/technical data
For the first collector
Two racks
For each additional collector
One additional rack
2. Fold out the first rack.
60°
45°
30°
3. Select the required installation angle.
Specifications/technical data
Installation angle
–
30°
–
45°
–
60°
1
2
4. Push the locking button
(1)
on the telescopic rail.
5. Pull the telescopic rail
(2)
into the desired installation
angle and allow the locking button to engage again.
1
2
3
1
6. Position the crossbeams
(1)
such that their fastening
holes lie between the corresponding threaded holes in
the telescopic rail.
7. To secure the rack, insert the fixing screw
(2)
through
all rails.
8. Secure the fixing screw
(2)
with the self-locking nuts
(3)
.
9. Tighten the nuts.