4 On-roof fitting and installation
12
Installation manual auroTHERM, auroTHERM plus 0020100571_03
4.1.8.1
n
Adjacent array configuration
Conditions
: Collector position: Horizontal
12
4
5 * / 12
20 **
200 - 300
200 - 300
200 - 300
200 - 300
1460 - 1660
▶
Define the clearances of the roof brackets.
▶
Ensure that the roof brackets have sufficient play.
–
Pre-installation dimension (*): = Finished installation
dimension (**) + 20-25 mm
Conditions
: Collector position: Vertical
20
4
5 *
/
2020
*
*
200 - 300
200 - 300
200 - 300
200 - 300
660 - 860
▶
Define the clearances of the roof brackets.
–
Pre-installation dimension (*): = Finished installation
dimension (**) + 20-25 mm
4.1.8.2
Array configuration on top of each
other
Conditions
: Collector position: Horizontal
12
4
5 * / 12
20 **
2500 * / 2
4
80 **
200 - 300
1460 - 1660
▶
Define the clearances of the roof brackets.
–
Pre-installation dimension (*): = Finished installation
dimension (**) + 20-25 mm
4.2
Carrying out the installation
The installation steps and notes in this manual apply to both
collector positions and array configurations. Any different
installation steps are clearly indicated in individual cases.
4.2.1
Installing roof brackets
4.2.1.1 Installing type P (for pantile)
1
3
2
1 Lower roof bracket
2 Top roof bracket
3 Middle roof bracket