4 Set-up
8
Installation and maintenance instructions atmoTEC exclusive, atmoTEC plus 0020214272_04
Information on the data
plate
Meaning
IP
IP rating/protection class
Cat. (e.g. II
2H3P
)
Unit category
Type (e.g. B
11
)
Gas-fired boiler types
2E, G20
–
20 mbar (2.0 kPa)
Gas group and gas connection
pressure as set at the factory
ww/yyyy (e.g. 11/2014)
Date of manufacture:
Week/year
PMW (e.g. 10 bar (1 MPa))
Permissible total excess pres-
sure during domestic hot wa-
ter generation
PMS (e.g. 3 bar (0.3 MPa))
Permissible total excess pres-
sure in heating mode
P
Nominal heat output range
T
max.
(e.g. 85 °C)
Max. flow temperature
Q
Heat input range
D
Nominal domestic hot water
draw-off rate
Heating mode
Domestic hot water generation
Barcode with serial number,
The 7th to 16th digits of the
serial number form the article
number
3.3
CE label
The CE label shows that the products comply with the basic
requirements of the applicable directives as stated on the
identification plate.
The declaration of conformity can be viewed at the manufac-
turer's site.
3.4
DVGW mark
The DVGW mark documents that the products comply with
all of the requirements of the DVGW VP 112 (test basis from
the German Association for Gas and Water Industry Asso-
ciation for granting the DVGW quality mark) in accordance
with the identification plate.
4
Set-up
4.1
Unpacking the product
1.
Remove the product from its box.
2.
Remove the protective film from all parts of the product.
4.2
Checking the scope of delivery
▶
Check that the scope of delivery is complete and intact.
Quantity
Designation
1
Heat generator
1
Unit mounting bracket
1
Lower unit cover (exclusive only)
1
Bag with small parts:
–
2 bolts
–
2 rawl plugs
–
2 washers
–
4 seals
1
Bag with connection material
–
Expansion relief valve discharge pipe
–
Seal
–
Union nut
1
Enclosed documentation:
–
Operating instructions
–
Installation and maintenance instructions
–
Mounting template
–
Guarantee card
–
Energy data sheet
–
Energy product label