9 Decommissioning
24
Installation instructions aroTHERM 0020217827_03
8.4
Carrying out check programmes
Menu
→
Installer level
→
Test programmes
→
Check pro-
grammes
You can use the check programmes to purge the circuits,
carry out manual de-icing and check the product's primary
function.
Display
Check programme
P01
Forced heating
P02
Forced cooling
P06
Manual de-icing
P10
Purging the heating circuit
P11
Purging the hot water circuit
9
Decommissioning
9.1
Temporary decommissioning
1.
Switch off the product.
2.
Disconnect the product from the power supply.
9.2
Permanently decommissioning
1.
Switch off the product.
2.
Disconnect the product from the power supply.
3.
Drain the product. (
4.
Dispose of or recycle the product and its components.
10 Recycling and disposal
Disposing of the packaging
▶
Dispose of the packaging correctly.
▶
Observe all relevant regulations.
▶
For detailed information refer to www.vaillant.co.uk.
10.1
Arranging disposal of refrigerant
Warning.
Risk of damage to the environment.
This heat pump contains the refrigerant R
410 A. The refrigerant must not be allowed
to escape into the atmosphere. R 410 A is a
fluorinated greenhouse gas covered by the
Kyoto Protocol, with a GWP of 2088 (GWP =
Global Warming Potential).
▶
Before the product is disposed of, have
the refrigerant which it contains com-
pletely drained into a suitable vessel so
that it can then be recycled or disposed of
in accordance with regulations.
The competent person who installed the heat pump must
dispose of the refrigerant.
Personnel who are approved for energy recovery must have
the relevant certification that corresponds to the valid regula-
tions.
11 Customer service
To ensure regular servicing, it is strongly recommended
that arrangements are made for a Maintenance Agreement.
Please contact Vaillant Service Solutions for further details:
Telephone: 0330
100
3461