Assembly and installation 5
0020217827_03 aroTHERM Installation instructions
11
▶
If the product is to be installed in areas where heavy
snow falls, ensure that the snow does not accumulate
around the product and that the minimum clearances
specified above are observed. If you cannot ensure this,
install an additional heat generator in the heating circuit.
A raised base is available as an accessory. In order to
adapt the product to higher levels of snow, only use the
Vaillant raised base.
5.1.3.2 Selecting the installation site
▶
Observe all valid regulations.
▶
Install the product outside the building.
▶
Do not install the product:
–
Near a heat source,
–
Near flammable materials,
–
Near ventilation openings for adjacent buildings,
–
Under deciduous trees.
▶
Note the following points when installing the product:
–
Prevailing winds,
–
The visual impression on the environment
▶
Avoid places where strong winds blow on the product's
air outlet.
▶
Point the fan away from nearby windows. Install noise
protection if necessary.
▶
Install the product on one of the following supports:
–
Concrete slab,
–
Steel T-beam,
–
Concrete block,
–
Elevating socket (Vaillant accessory),
▶
Do not expose the product to dusty or corrosive air (e.g.
near unsecured streets).
▶
Do not install the product near ventilation shafts.
▶
Prepare the routing for the electrical wires.
dB(A)
dB(A)
▶
Note any noise emissions from the fan and compressor.