Safety 2
0020058722_04 Air/flue gas system Installation manual
7
2.3.9
Inspect/clean chimneys to which former
solid fuel boilers were once connected
We recommend that you have chimneys inspected and
cleaned by a chimney sweep before the flue gas pipe is
installed if these chimneys were previously used to divert
flue gas away from solid-fuel-fired boilers but should now
supply combustion air. If it is not possible to adequately in-
spect/clean the chimney (e. g. due to construction features),
you can
–
use a separate air supply or
–
use open-flued operation for the system.
2.3.10 Risk of corrosion in the product caused by
using a chimney to which the former oil-
fired boiler was once connected
Chimneys that previously diverted the flue gas away from oil-
fired boilers should not be used to supply combustion air.
The combustion air may be charged with chemical deposits
and this leads to corrosion in the product.
2.3.11 Risk of fire due to insufficient clearance
▶
Ensure that the flue gas pipe outside the shaft has a min-
imum clearance of 5 cm from flammable components.
2.3.12 Moisture damage caused by incorrect
installation location of the inspection elbow
An incorrect installation location leads to condensate leaking
from the lid of the opening for cleaning and may lead to cor-
rosion damage.
▶
Install the inspection elbow in accordance with the illus-
tration.
2.3.13 Moisture damage caused by incorrect
installation location of the inspection T-
piece
An incorrect installation location leads to condensate leaking
from the lid of the opening for cleaning and may lead to cor-
rosion damage.
▶
Install the inspection T-piece in accordance with the illus-
tration.
2.3.14 Material damage due to improper use
and/or unsuitable tools
Improper use and/or the use of unsuitable tools may result in
material damage.
▶
Always use a suitable open-end spanner to tighten or
undo threaded connections.
▶
Do not use pipe wrenches, extensions, etc.
2.4
Intended use
2.4.1
Intended use of the Vaillant air/flue gas
systems
Vaillant air/flue gas systems are constructed using state-of-
the-art technology in accordance with the recognised safety
rules and regulations. Nevertheless, there is still a risk of
injury or death to the system operator or others or of damage
to the products and other property in the event of improper
use or use for which the products are not intended.
The Vaillant air/flue gas systems named in this manual must
only be used in combination with the product types named in
this manual.
Any other use that is not specified in these instructions, or
use beyond that specified in this document, shall be con-
sidered improper use.
Intended use includes the following:
–
observance of accompanying operating, installation and
servicing instructions for the Vaillant product as well as
for all other components of the system
–
installing and fitting the product in accordance with the
product and system approval
–
compliance with all inspection and maintenance condi-
tions listed in the instructions.
2.4.2
CE certification
The products are certified as boiler systems with attached
flue gas installation according to the EU gas appliances dir-
ective 90/396/EEC or 2009/142/EC.