INSTALLATION OF THE HORIZONTAL AIR/FLUE DUCT (REAR OUTLET)
(TURBOMAX AND THERMOCOMPACT ONLY)
20
For thermoCOMPACT 620, 624, 628,
turboMAX pro 24, 28, turboMAX plus
824, 828:
• Refit the collector hood (
1
).
Remove blank and refit funnel.
• Reconnect the electrical cables to
the fan.
• Gently push the flue duct
downwards to the left.
• Slide the fan (
2
) into position on
flue collector hood (
3
). Ensure that
the flue gas connector (
5
) engages
over the end of the flue duct and
the flange on the back of the fan
plate locks in to the collector
hood.
• Secure the fan to the flue collector
hood using only one screw (
4
).
• Reconnect the air pressure tubes to
the fan, ensuring that the air tubes
are connected to the correct
nipple.
Note: Blue tube connects to the rear
most fan outlet spigot.
• On combustion chamber cover
front swap top left hand rubber
bung with the metal hole bung.
• Reassemble the boiler in reverse
order.
• Complete the installation as
detailed in the boiler Installation
and Servicing instructions.
2
5
3
4
4
1
Fig. 3.11
LAS Euro B/S 058_2.eps