System 0020185684 1
0020251825_01 System installation instructions
1
System installation instructions
1
System 0020185684
VWS 36/4.1 230V with gas-fired boiler and VRC 700
Caution.
Risk of material damage caused by incomplete installation.
This drawing is a basic representation and does not replace complete planning. This drawing does not
contain all of the required valves and safety fittings for a complete installation.
▶
Observe the applicable national and international laws, standards and guidelines.
▶
When planning, installing and subsequently operating this system, you must observe all the install-
ation and operating instructions available for the product, the relevant accessories and for any other
component.
▶
The responsibility for design lies with the responsible company.
1.1
Basic hydraulic diagram 0020185684
1
Heat generator
2
Heat pump
3e
Circulation pump
5
Monovalent domestic hot water cylinder
8a
Expansion relief valve
8b
Potable water expansion relief valve
8c
Safety group
–
drinking water connection
8e
Heating diaphragm expansion vessel
8f
Diaphragm expansion vessel
–
potable water
9a
Single-room temperature control valve (thermo-
static/motorised)
9c
Flow regulator valve
9h
Filling/draining cock
9j
Tamper-proof capped valve
10c
Non-return valve
10e
Line strainer with magnetite separator
12
System control
12g
eBUS bus coupler
12k
Limit thermostat
12m
Outdoor temperature sensor
DHW
Cylinder temperature sensor