background image

2 Notes on the documentation

6

Operating instructions HOME 0020224339_00

2 Notes on the

documentation

2.1 Observing other applicable

documents

You must observe all operating instruc-
tions enclosed with the system compon-
ents.

2.2 Storing documents

Keep this manual and all other applic-
able documents safe for future use.

2.3 Applicability of the

instructions

These instructions apply only to:

Product article number

Article
number

Gas Coun-
cil Number

HOME REGULAR
12 -A (H-GB)

0010019925 41-044-88

HOME REGULAR
15 -A (H-GB)

0010019926 41-044-89

HOME REGULAR
18 -A (H-GB)

0010019927 41-044-90

HOME REGULAR
25 -A (H-GB)

0010019928 41-044-92

HOME REGULAR
30 -A (H-GB)

0010019929 41-044-93

3 Product description

3.1 CE label

The CE label shows that the products
comply with the basic requirements of the
applicable directives as stated on the iden-
tification plate.
The declaration of conformity can be
viewed at the manufacturer's site.

3.2 Information on the

identification plate

The identification plate is mounted on the
underside of the product in the factory.
The identification plate keeps record of
the country in which the product is to be
installed.

Information
on the identi-
fication plate

Meaning

Barcode with serial number

Serial number

For quality control purposes;
3rd and 4th digits = year of
production
For quality control purposes;
5th and 6th digits = week of
production
For identification purposes;
7th to 16th digits = product
article number
For quality control purposes;
17th to 20th digits = place of
manufacture

HOME REGU-
LAR

Product description

2H, G20 -
20 mbar
(2 kPa)

Factory setting for type of
gas and gas connection
pressure

Cat.

Approved gas category

Condensing
technology

Efficiency class of the boiler
in accordance with EC Dir-
ective 92/42/EEC

Type: Xx3(x)

Permissible flue gas connec-
tions

PMS

Maximum water pressure in
heating mode

PMW

Maximum water pressure in
hot water handling mode

V/Hz

Electric connection

W

Max. electrical power con-
sumption

IP

Level of protection
Heating mode

Summary of Contents for 0010019925

Page 1: ...or Operating instructions HOME REGULAR GB IE Operating instructions Publisher manufacturer Vaillant GmbH Berghauser Str 40 D 42859 Remscheid Tel 49 21 91 18 0 Fax 49 21 91 18 28 10 info vaillant de ww...

Page 2: ...8 4 2 Basic display 8 4 3 Selecting the operating mode 8 4 4 Setting the hot water temperature 9 4 5 Setting the heating flow temperature 9 4 6 Product settings 9 4 7 Switching the product to standby...

Page 3: ...ng installations and for hot wa ter generation Intended use includes the fol lowing observance of the operating instructions included for the product and any other system components compliance with al...

Page 4: ...etent person 1 3 4 Risk of death from escaping flue gas If you operate the product with an empty condensate siphon flue gas may escape into the room air In order to operate the product ensure that the...

Page 5: ...tion and room air Sprays solvents chlorinated cleaning agents paint adhes ives ammonia compounds dust or similar substances may lead to corrosion on the product and in the air flue pipe Ensure that th...

Page 6: ...at the manufacturer s site 3 2 Information on the identification plate The identification plate is mounted on the underside of the product in the factory The identification plate keeps record of the...

Page 7: ...ode DSN Specific product code CE label section Read the instructions Recycling and disposal section GC no Gas council number 3 3 Design of the product 1 1 Control elements 3 4 Overview of the operator...

Page 8: ...t has two operating levels Operator operating level This provides access to the most important informa tion and setting options that do not re quire any particular prior knowledge Operating level for...

Page 9: ...ed by the control ler with heating mode activated Set the maximum heating flow temper ature on the boiler Page 9 Set the room temperature on the con troller The actual heating flow temperature is set...

Page 10: ...2 Caring for the product Caution Risk of material damage caused by unsuitable clean ing agents Do not use sprays scouring agents detergents solvents or cleaning agents that con tain chlorine Clean the...

Page 11: ...n annual ser vice must be carried out by a competent person approved at the time by the Health and Safety Executive one year after install ation The cost of this annual service is not included in the...

Page 12: ...tored The product is switched off Switch on the product The heating flow temperature is set too low or to the Heating off position and or the hot water temperature is set too low Set the heating flow...

Page 13: ......

Page 14: ......

Page 15: ......

Page 16: ...0207 022 0928 Vaillant Service Solutions 0330 100 3461 Spares Technical Enquiries 01773 596615 info vaillant co uk technicalspares groupservice co uk www vaillant co uk These instructions or parts th...

Reviews: