Appendix
28
Installation and maintenance instructions ecoVIT exclusiv 0020258610_00
Code
Parameter
Values
Unit
Explanation, selection, increment
Default
setting
Own
setting
Min.
Max.
D.014
Pump speed target value
30
100
%
Speed-controlled heating pump
setting
- : Auto
30-100% fixed value setting
- = Auto
D.015
Pump speed actual value
Current value
%
Current pump output for the speed-
controlled heating pump
–
Not ad-
justable
D.017
Control type
0
1
–
0: Flow temperature control
1: Return temperature control
0
D.018
Pump operating mode
1
3
–
1: Overrun (comfort)
3: Continuous (eco)
1
D.020
Max. DHW temperature
target value
50
70
℃
Max. setting for cylinder target
value
1
65
D.022
DHW demand
Current value
–
External cylinder charging, plug
C1-C2
0: Off
1: On
–
Not ad-
justable
D.023
Heating mode status
Current value
–
Summer/winter mode (heating
off/on)
0: Heating off (summer mode)
1: Heating on
–
Not ad-
justable
D.025
Ext. eBUS signal: Cylinder
charging
Current value
–
Hot water generation enabled by
eBUS control
0: Off
1: On
–
Not ad-
justable
D.026
Auxiliary relay
1
6
–
Internal accessory relay at X6 (pink
plug)
1: Circulation pump
2: Second external pump
3: Cylinder charging pump
4: Flue non-return flap/extraction
hood
5: External gas valve
6: Ext. fault message
1
D.027
Accessory relay 1
1
6
–
Switching accessory relay 1 for 2 in
7 multi-functional module access-
ory
1: Circulation pump
2: Second external pump
3: Cylinder charging pump
4: Flue non-return flap/extraction
hood
5: External gas valve
6: Ext. fault message
1
D.028
Accessory relay 2
1
6
–
Switching accessory relay 2 for 2 in
7 multi-functional module access-
ory
1: Circulation pump
2: Second external pump
3: Cylinder charging pump
4: Flue non-return flap/extraction
hood
5: External gas valve
6: Ext. fault message
2
D.030
Fuel valve actuation
Current value
–
0: Off
1: On
–
Not ad-
justable
D.033
Fan speed target value
Current value
rpm
–
–
Not ad-
justable
D.034
Fan speed actual value
Current value
rpm
–
–
Not ad-
justable