background image

 

 

Technical Manual 

 

Instructions for installation, 
operation and maintenance  

669 

 

T-SENSE

®

 

Optical Torque Measuring systems  
and PEM4 stand alone 

Publication nr 

TIB-669-GB-1117 

Supersedes 

 

 

 

Summary of Contents for T-SENSE

Page 1: ...Technical Manual Instructions for installation operation and maintenance 669 T SENSE Optical Torque Measuring systems and PEM4 stand alone Publication nr TIB 669 GB 1117 Supersedes...

Page 2: ...ts 14 7 3 Explanation of the parameters 14 7 3 1 Torque 14 7 3 2 Shaft speed 14 7 3 3 Power 14 7 3 4 Thrust option 14 7 4 Operating instructions PEM4 touchscreen 15 7 4 1 Operating menus 15 7 5 How to...

Page 3: ...2 19 SPARE PARTS 25 20 WARRANTY CONDITIONS 26...

Page 4: ...stallation and operation read this manual completely before installing the equipment and starting operations For any additional information contact VAF Instruments B V Tel 31 78 618 3100 Vierlinghstra...

Page 5: ...surement optional is provided Displaying of parameters The PEM4 touch screen can be installed in a control cabinet or control panel Remark Optional 4 20 mA analogue output can be integrated in the sta...

Page 6: ...box for at least one hour at the location where the system will be installed When the equipment is taken out of the box please leave the special protection supplied with the equipment as long as possi...

Page 7: ...checked and corrected 6 1 TO RECORD NAMEPLATE DATA This information is required when contacting the supplier for any reason Date of delivery xx xx xxxx Serial number xxxx Stator version xxxx Interface...

Page 8: ...of touch screens which can be connected by Ethernet connection is two Figure 2 T Sense torque sensor connected to one PEM4 touch screen Figure 3 Example of T Sense torque sensor connected to two PEM4...

Page 9: ...he stator control box and power supply to the backside bottom of the PEM4 touch screen in accordance with Figure 4 Figure 4 ON OFF switch and communication ports at backside bottom of PEM4 touch scree...

Page 10: ...to the system as described in Figure 5 For the use of two PEM4 screens a Ethernet switch is necessary Check for correct power supply and integrity of external wiring connections Turn on power and obse...

Page 11: ...gs of the system Switch off the power supply of the PEM4 display Wait for 1 minute and then repower the PEM4 Enter password 5678 end press login The screen below will appear Change the Address to http...

Page 12: ...rrect press Next Set the DNS address to 255 255 255 0 and press Done The screen below will appear Press Confirm to save settings Next switch of the power supply of the PEM4 wait for 1 minute and repow...

Page 13: ...s Cable specification IC 01 Integrated antenna cable 5m VAF supply IC 02 Integrated stator cable 5m VAF supply IC 04 Power supply 115 230 VAC cable 3 x 1 5 mm 2 flex strands IC 05 Power supply 24 VDC...

Page 14: ...s applied the PEM4 touch screen will display below parameters in addition Propeller thrust kN Thrust power quotient kN MW 7 3 EXPLANATION OF THE PARAMETERS 7 3 1 Torque The torque signal measured in t...

Page 15: ...By pressing at the touch screen buttons text fields characters pages are selected Browsing through the menus by tapping on the different pages at the top of the touch screen will help you to find the...

Page 16: ...e shaft are available at the lower part of the screen The Total Energy value jumps from kW to MW to GW min 0 000 kW and max 9999 GW The Total Revolutions value jumps from E3 to E6 to E9 respectively 1...

Page 17: ...nverse Pushing Inverse will change the button back to standard again 7 5 3 2 Settings menu clock Figure 11 Settings menu clock 7 5 3 3 Settings menu Ethernet settings Figure 12 Settings menu Ethernet...

Page 18: ...g all essential data in case you to have to contact VAF Instruments regarding your T Sense torque measuring system 7 5 4 Alarm screen Figure 14 Alarm Screen In case the PEM4 touch screen detects that...

Page 19: ...r minute rpm Total energy is calculated from the integrating shaft power over time Total energy E Total energy kWh The thrust quotient indicates the amount of thrust generated per MW propulsion power...

Page 20: ...e without any errors Disconnect all the input and output wires Store the PEM4 in a box in a cool and dry place so that the PEM4 cannot be damaged 12 MALFUNCTION AND SEND FOR REPAIR If the PEM4 stops w...

Page 21: ...n between the PEM4 and the stator control box is broken Check wires for damage Check the connections in the stator control box or at the PEM4 touch screen 16 CERTIFICATES For a torque measuring system...

Page 22: ...22 17 DRAWINGS Drawing 1 0815 1023...

Page 23: ...23 Drawing 2 0815 2037...

Page 24: ...24 Drawing 3 0815 2038...

Page 25: ...itoring system CPU Central Processing Unit TFT Thin Film Transistor Liquid Crystal Display PCAP Projected Capacitive LED Light Emitting Diode LCD Liquid Crystal Display PT100 Temperature sensor type P...

Page 26: ...d installed All costs accruing above the single obligation described in the first sentence such as are not restricted to shipment costs travelling and accommodation costs or disassembly or assembly co...

Page 27: ...product or allows it to be commenced then every agreement with regard to guarantee shall be void 6 Claims regarding defects must be submitted in writing as quickly as possible and not later than 14 d...

Page 28: ...etherlands P O Box 40 3300AADordrecht The Netherlands T 31 78 618 3100 sales vaf nl www vaf nl Specifications subject to change without notice VAF Instruments B V is an ISO 9001 Certified Company Agen...

Reviews: