background image

2

  

3

Important information .............................................. 3
General installation ...................................................3
Operating Specifications ...........................................3
Contents of packaging ..............................................4
Dimensions ................................................................5
Installation - Quick guide ..........................................6
Installation .................................................................8
Installation - Shower ...............................................11

Contents

Please read these instructions carefully before starting installation and keep for  

future reference.
Remove all packaging and check the product for missing parts or damage before 

starting installation.
Any alterations made to this product and fittings may infringe water regulations and 

will invalidate the guarantee.
The installation must comply with all Local/National Water Supply Authority 

Regulations/Byelaws and Building and Plumbing Regulations.  

To be installed in accordance with BS EN806.
We strongly recommend that you use a qualified and registered plumber.

General installation

Operating Specifications

Important - please read

Operating Pressure
Minimum operating pressure

 1 bar 

Maximum operating pressure

 5 bar

This fitting is a mixing device and therefore water supplies should be reasonably 

balanced.
When installed, the fitting must comply with the requirements of the Water Supply 

(Water Fittings) Regulations 1999 and Scottish Byelaws 2004. 

For further information, contact the Water Regulations department of your local water 

supplier (see the WRAS website www.wras.co.uk for details) or the Water Regulations 
Advisory Scheme by email (info

@

wras.co.uk) or telephone: 01495848454.

Before making any inlet pipe connections, all supply pipes MUST be thoroughly flushed 

to remove debris. Failure to do so could result in damage or low flow from the mixer 

unit.
The fitting of isolating valves to the inlet feeds is advised for ease of maintenance.
Please take great care when installing this mixer not to damage its surface.
Please note if installing in an enclosed environment, access should be left for servicing 

and maintenance. No costs relating to inadequate access can be accepted.

Summary of Contents for OMIKA OMI-133

Page 1: ...p for future reference Installation Guide where inspiration flows Vado Wedmore Road Cheddar Somerset England BS27 3EB tel 01934 744466 fax 01934 744345 aftersales vado com www vado com This instruction booklet covers model OMI 133 Version 1 1 8 17 ...

Page 2: ...ressure Minimum operating pressure 1 bar Maximum operating pressure 5 bar This fitting is a mixing device and therefore water supplies should be reasonably balanced When installed the fitting must comply with the requirements of the Water Supply Water Fittings Regulations 1999 and Scottish Byelaws 2004 For further information contact the Water Regulations department of your local water supplier se...

Page 3: ...ers x 8 Tap upstand Floor Mounted Bath Shower Mixer 133 OMIKA Keep for future reference Installation Guide WHERE INSPIRATION FLOWS OMIKA Floor Mounted Bath Shower Mixer User Guide Accessory box Shower hose Base Base connection Valve dimensions 75mm 215mm 67mm 110mm 30mm 154mm 100mm Ø40mm 870mm 16 5mm ...

Page 4: ...6 7 Installation Quick guide Installation Quick guide 1 3 4 2 1 2 3 4 0 5 1 2 3 4 0 5 1 2 3 4 0 5 1 2 3 4 0 5 1 2 3 4 0 5 1 2 3 4 0 5 1 2 3 4 0 5 1 2 3 4 0 5 105mm x 3 5 7 9 6 8 10 90mm 90mm ...

Page 5: ... e g expansion bolts for concrete or coach screws for wood Installation 105mm Slide the shroud onto base of upstand To ensure smooth movement of shroud and prevent scratching during installation please use a suitable silicone based lubricant Be sure to keep the shroud level and raise both sides equally Using the 4 supplied cap screws and washers secure the base connection onto the bottom of the ta...

Page 6: ...dset Rubber washer Nut end of hose Installation Slide the shroud down until it makes connect with the floor Be sure to keep the shroud level and lower both sides equally Finish the floor covering down to a dimension of 90mm x 90mm Keep the tap upstand protected while the floor is being completed Place the base connection onto the base Rotate the tap upstand until the outlet is in the desired posit...

Page 7: ...ocess This can be done via the VADO website or via phone to our aftersales team Registration must be completed within 6 months from date of purchase Under the extended guarantee period VADO will at its option offer to supply any replacement product or component part assessed to be defective SEE NOTE 3 The guarantee whether standard or extended is non transferable to any subsequent owner All claims...

Page 8: ...n expect exceptional product quality and outstanding customer service This product has passed through stringent quality assurance processes coupled with demanding lifecycle mechanical testing to ensure it reaches the exacting standards that allow us to offer our premium 12 year guarantee We work to ensure our product designs are harmonious with all sanitaryware so when you choose VADO your choice ...

Page 9: ...to ensure the appearance is retained We recommend cleaning all products with a soft damp cloth ONLY and advise strongly against the use of all aggressive corrosive cleaning products i e powders and liquids If these instructions are not followed this may invalidate your guarantee in the event of a problem occurring Notes ...

Page 10: ...BRACK 1 5 Handset OMI HANDSET C P 1 6 Shower Hose SH 012 150 CP LB 1 7 Shroud OMI 133 SHROUD C P 1 8 Adaptor OMI 133 CONC ADAPTOR 1 9 Base CON 133 BR 1 10 Installation guide User manual 1 Floor Mounted Bath Shower Mixer 133 OMIKA Keep for future reference Installation Guide WHERE INSPIRATION FLOWS OMIKA Floor Mounted Bath Shower Mixer User Guide 8 2 4 10 3 7 6 1 5 9 ...

Reviews: