Installation
Hot inlet
Outlet
Before installing your new mixer, flush through the pipe work to ensure removal of
debris, turn off the water supply.
Warning!
Please check for any hidden cables and pipes before drilling holes in
the wall.
The valve must be set into the wall by 45-65mm (see dimension page).
Note:
The valve must be connected to rigid pipe work for support.
Keep plastic cover in place during installation to protect the product's chrome finish.
Make all connections to the valve. Connect hot supply to left inlet of the valve and
cold supply to right inlet.
Connect the outlet to the desired channel.
Finish the wall leaving a sufficient gap around the plastic cover to house the
rubber plate gasket. Keep the final finished wall surface between the min and max
dimensions.
Cold inlet
Plastic cover
Installation
Slide the plate over the valve, push onto the wall until it makes contact.
Carefully slide the control handle onto the valve and secure in position with the
grub screw located within the handle using the hexagonal key supplied, replace the
screw cover.
Note:
If the valve is sited within in a wet environment, it is recommended that once
the valve is installed the plate is sealed with an adequate of sealant around three
sides to provide a water-tight seal between the plate and the wall material, leaving
the bottom edge free to allow for maintenance purposes.
Valve
Plate
Grub screw
Handle
Screw cover