Maintenance and service
38
11.07.2011
ver. 2
4.4
Unsynchronized wing folding
Figure 4.8
Applies to NZA 900-1000
In the case of unsynchronized wing folding on NZA 900-1000 cultivators, the probable cause is
binding of the slide inside the valve block. See ”
4.5 Valve block cleaning” on page 38
:
4.5
Valve block cleaning
Figure 4.9
Applies to NZA 900-1000
A
Release the pressure in the hydraulic hoses.
B
Detach the hydraulic hoses connected to the valve block.
C
Unscrew the valve block from the piston support.
D
Dismantle the entire valve block and clean all parts in paraffin or similar solvent. Blow dry
with compressed air.
E
Lubricate all the internal parts with oil. Check that the slide in the valve moves freely without
binding. Assemble the valve block.
F
Clean all hydraulic connections thoroughly before assembly.
G
Then mount the valve block on the cultivator.