WideSHOT WallVIEW SR
WideSHOT WallVIEW SR System Document Number 342-0695 Rev A
Page 7 of 20
Rear Panel Connections with Feature Call-outs
Image: WideSHOT HD Camera
1) RS-232 & IR Out:
The RS-232 accepts modified VISCA protocol for camera control, as well as transmits IR
signaling received by the front IR receiver, which can be transmitted to third party devices
2) EZ Power/Video Port:
This RJ-45 connector is only used with the Quick-Connect SR, Quick-Connect DVI-D/HDMI SR Interface, Quick-
Connect USB and USB Mini Interfaces to supply power and return HSDS (differential) video from the camera
over Cat-5 cable up to distance of 150’ (45.72m).
3)
Dip Switch Settings:
Settings for IR remote frequency, IR receiver on/off, image flip, test bars and defaults can be configured on these
switches. See the Switch Settings page for additional information. The dip switch settings are as follows:
4) HD Video Select:
A rotary switch allows the user to choose the video output resolution for the camera. After setting or changing
the resolution, reboot the camera to ensure proper operation. If an unassigned rotary selection position is
chosen (3, 9, A, B, C or D), the camera will output a medium grey video privacy mask. The HD Video Select
Rotary Switch Settings are as follows:
Rotary
Resolutions
Rotary
Resolutions
0
720p/59.94
8
576p/59.94
1
1080i/59.94
9
--
2
1080p/59.94
A
--
3
--
B
--
4
720p/50
C
--
5
1080i/50
D
--
6
1080p/50
E
1080p/29.97
7
480p/59.94
F
1080p/25
Dip Switch
Function
1
Up = IR1, Down = IR2
2
Up = IR 1 or 2, Down = IR3
3
Up=IR ON, Down = IR OFF
4
Up = Normal Image, Down = Image Flip
5
Test Bars
6
Update Position - Leave UP unless updating firmware
All Down
Reset to Defaults - with power cycle
①
②
③
④
Point the notch in the
switch stem to assign
the rotary position (the
camera is on Position 1
1080i/59.94).
Important Notes:
1) For IP or USB 2.0 Streaming, use
position “0” (720p/59.94) for best results
2) Set the rotary switch to an unassigned
position and a medium grey privacy
mask is displayed.