HD-USB Inquiry List
Inquiry Command
Command
Response Packet
Comments
CAM_PowerInq
8x 09 04 00 FF
y0 50 02 FF
y0 50 03 FF
On
Off(Standby)
CAM_ZoomPosInq
8x 09 04 47 FF
y0 50 0p 0q 0r 0s FF
pqr: 0-0x6B3
CAM_FocusPosInq
8x 09 04 48 FF
y0 50 0p 0q 0r 0s FF
pqrs: Focus Position
CAM_BacklightModeInq
8x 09 04 33 FF
y0 50 02 FF
y0 50 03 FF
On
Off
CAM_MemoryInq
8x 09 04 3F FF
y0 50 0p FF
p:Preset 0-0xf
Pan-TiltMaxSpeedInq
8x 09 06 11 FF
y0 50 pp qq FF
pp:Pan 0x01-0x18
qq:Tilt 0x01-0x14
Pan-tiltPositionInq
8x 09 06 12 FF
FF y0 50 0p 0p 0p 0p 0q 0q 0q 0q FF
pppp: Pan 0x8044-0x7FB2
qqqq: Tilt 0xE890-0x4C2C
TallyInq
8x 09 7E 01 0A FF
y0 50 02 FF
y0 50 03 FF
On
Off
PresetSpeedInq
8x 09 7E 01 0B FF
y0 50 pp qq rr FF
pp:Pan 0x01-0x18
qq:Tilt 0x01-0x14
rr:Zoom 0x00-0x07
Motor Config
8x 09 7E 01 70 FF
y0 50 00 FF
y0 50 01 FF
Hard Motor Stops
Soft Motor Stops
A
F
INAL
N
OTE ABOUT
S
OFTWARE
R
ELEASES
:
Since there is better than 1/2 a page to fill up here, a note regarding the software releases and the intent of the
product lifecycle of the HD-USB camera is included.
The intent of releasing the HD-USB camera with full USB 2.0 implementation and waiting for Release 2.0 for full
H.264 implementation was to ensure that the H.264 streaming applications could all be adequately tested and
confirmed 100% operational.
The USB 2.0 implementation is in high demand and we are ready for Release 1.0 of the camera strictly for USB
2.0 soft client conferencing programs.
While there is some rudimentary Ethernet functionality in Release 1.0, it was included mainly as a means to
upgrade/update the software for future software releases and added functionality. In any case, it is recommended
that anyone using the Ethernet connectivity use the Static IP addressing for now.