background image

Edge Equipment Enclosures 

.  Edge Equipment Enclosures - Document Number 342-0026 Rev. A   

 

 

 

         Page 2 of 12 

Vaddio Edge Equipment Enclosure Overview: 

The Edge Equipment Enclosures mount to any of the Edge 
Monitor stands and there are three (3) different models, all of 
which have cable management features, a vented rear panel 
for cooling/wiring access through the rear of the enclosure and 
smoked acrylic doors to allow IR signals to pass.  Each Edge 
series enclosure is powder coated instead of painted for a 
durable and lustrous finish.  The Top and bottom panels are a 
semi gloss graphite grey nebula and features beveled edges 
for added appeal. The sides powder coated a complementary 
light grey color that matches the powder coating on the Edge 
series monitor stands.          

 
 
The Models covered in this manual include: 
EE-Shelf:

  Equipment Enclosure with Shelf (PN: 798-0500-000) Assembled 

EE-Shelf:

  Equipment Enclosure with Shelf (PN: 798-0500-001) Flat Packed 

The EE-Shelf model includes one (1) internal shelf and has internal dimensions of 11” (280mm) H x 
20.625” (524mm) W x 14” (356mm) D 

 
EE-6RU:

  6-Space Rack Mount Equipment Enclosure (PN: 798-0600-000) Assembled 

EE-6RU:

  6-Space Rack Mount Equipment Enclosure (PN: 798-0600-001) Flat Packed 

With the same basic features of the EE-Shelf, the EE-6RU include black anodized rack rail to fit six (6) 
spaces (10.5” / 267mm) of rack mount equipment.  

Internal Dimensions: 10.5” (267mm) H x19.125” (486mm) 

W x 13.5” (343mm) D to rails 

 

 
EE- 9RU:  

9-Space Rack Mount Equipment Enclosure (PN: 798-0900-000) Assembled

 

EE- 9RU:  

9-Space Rack Mount Equipment Enclosure (PN: 798-0900-001) Flat Packed

 

The EE - 9RU is a larger rack mount enclosure (pictured above right) featuring black anodized rack rail 
and nine (9) spaces (15.75” / 400mm) of rack mount equipment. 
 
The Flat Packed (unassembled) equipment enclosures will be covered by this manual first and the 
assembled version will follow. The final section will contain directions on mounting the enclosure to the 
Edge videoconferencing cart. 

 
 
Intended Use: 

Before operating the system, please read the entire manual thoroughly. The product was designed, built 
and tested for use indoors.  The use of alternate connectors, other than the provided parts, or outdoor 
use has not been tested and could damage the product and/or create a potentially unsafe operating 
condition. 

 

Save These Instructions: 

The information contained in this manual will help you assemble and install your system.  If these 
instructions are misplaced, Vaddio keeps copies of Specifications, Installation and User Guides and most 
pertinent product drawings for the Vaddio product line on the Vaddio website.  These documents can be 
downloaded from 

www.vaddio.com

 free of charge. 

 

Important Safeguards: 

Read and understand all instructions before using.  Do not operate any device if it has been dropped or 
damaged. In this case, a Vaddio technician must examine the product.  To reduce the risk of 
disintegration, do not immerse in water or other liquids, avoid explosives and extremely wet and/or 
extremely humid conditions. 

 

 
 

Summary of Contents for Edge EE-Shelf

Page 1: ... PN 798 0500 000 Assembled EE Shelf Equipment Enclosure with Shelf PN 798 0500 001 Flat Packed EE 6RU 6 Space Rack Mount Equipment Enclosure PN 798 0600 000 Assembled EE 6RU 6 Space Rack Mount Equipment Enclosure PN 798 0600 001 Flat Packed EE 9RU 9 Space Rack Mount Equipment Enclosure PN 798 0900 000 Assembled EE 9RU 9 Space Rack Mount Equipment Enclosure PN 798 0900 001 Flat Packed Edge Videocon...

Page 2: ...6mm W x 13 5 343mm D to rails EE 9RU 9 Space Rack Mount Equipment Enclosure PN 798 0900 000 Assembled EE 9RU 9 Space Rack Mount Equipment Enclosure PN 798 0900 001 Flat Packed The EE 9RU is a larger rack mount enclosure pictured above right featuring black anodized rack rail and nine 9 spaces 15 75 400mm of rack mount equipment The Flat Packed unassembled equipment enclosures will be covered by th...

Page 3: ... bag 1 Magnetic Door Catch dual cylinder magnetic to door handles 12 Cams Phillips head twist to lock 12 Connecting Posts for Cams to connect 4 1 Dry Wall Screws 4 10 32 x Pan Head Machine Screws 2 Vent Panel Retention Clips 2 Door Handles in plastic bag with foam rubber pads EE 6RU 6 Space Rack Mount Equipment Enclosure PN 798 0600 000 Assembled EE 6RU 6 Space Rack Mount Equipment Enclosure PN 79...

Page 4: ...ening 1 Vent Panel black melamine 2 Smoke tinted acrylic doors 1pr Rack Rails attached to spacer block 2pr Door Hinges in plastic bag 1 Magnetic Door Catch dual cylinder magnetic to door handles 12 Cams Phillips head twist to lock 12 Connecting Posts for Cams to connect 4 1 Dry Wall Screws 4 10 32 x Pan Head Machine Screws 2 Vent Panel Twist Clips 2 Door Handles in plastic bag with foam rubber pad...

Page 5: ...catch with two long Phillips screws from the package to the top as shown in the picture below e After six 6 connecting posts two 2 bushings and the magnetic catch are attached the top should look like the picture below 2 Preparing the Bottom for Assembly Lay the bottom on a flat clean surface with the beveled edge as shown in the picture below Repeat steps b c and d from the section above The six ...

Page 6: ...holes with the arrow facing the top and bottom edge of the side b Finish the insertion of the cams on both sides and when finished it should look like the image below c Lay the back on a smooth clean surface with the groove up as shown below Insert vent into back and install vent panel retention clips into predrilled locating holes to hold vent in place as shown below d The back panel with the ins...

Page 7: ...the groove in the bottom at the back of the bottom shown in b c Turn the three cams clockwise until they lock about a half turn as shown in c d Insert back into groove in side and bottom as shown below d Make sure the brown clips are on the out side of the enclosure Repeat step b and c for other side as shown in e e Match the connecting posts of the top with the sides and slide together as shown b...

Page 8: ... the 2 nd door Repeat steps a b making sure to apply the strike plates foam pad and handle on the opposite sides to create a pair of doors 6 Installing the Rack Rails for the Rack Enclosure Models Before putting on the doors fasten the rack rail and spacer block to the enclosure with the 1 drywall screw Slide the screw through the predrilled hole and turn it into the location holes on both sides o...

Page 9: ...shing and hold it here while the door is slid into place as shown c Slide the door to the back edge of the hinge and tighten the rear screw on the top and bottom hinge Repeat this procedure for the other door d While holding the door loosen the screws on the hinge to adjust the doors to get an even gap in the middle approx 1 8 When the doors are aligned tighten all the screws on the hinges Hinge i...

Page 10: ...ign the holes in the arms with the holes in the bottom of the enclosure d Insert one screw in the front hole and turn it into the threaded T nut but do not tighten it fully to allow for easy alignment of the other three 3 screws e Once all four 4 screws are threaded tighten all the screws with a Phillips screw driver Thread four 4 10 32 x screws through extension arms into the T nuts in the bottom...

Page 11: ...r costs and or replacement Return Material Authorization RMA number Before returning a product for repair or replacement request an RMA from Vaddio s technical support Provide a technician with a return phone number e mail address shipping address and product serial numbers and describe the reason for repairs or returns as well as the date of purchase and proof of purchase Include your assigned RM...

Page 12: ...Edge Equipment Enclosures Edge Equipment Enclosures Document Number 342 0026 Rev A Page 12 of 12 ...