Switch Settings
The camera uses DIP switches to determine certain camera functions.
A label on the bottom of the camera provides a quick reference for setting the switches.
When the camera is right side up, switches are in their default positions when they are up.
IR Frequency Selection:
The IR Remote Commander can control up to three cameras in the same room
with different IR frequencies. Use
switches 1 and 2
to select the frequency to identify the camera as
camera 1, 2, or 3; then use the Camera Select buttons at the top of the remote to select the camera you
want to control.
Inverted operation:
If mounting the camera upside-down, set
switch 3
to the DOWN position: IMAGE
FLIP ON.
Switch 4
is not currently used.
Note
The web interface provides additional switch settings for baud rate, status indicator behavior, and soft
client compatibility.