background image

Warranty Information

See Vaddio Warranty, Service and Return Policies posted on

support.vaddio.com

for complete details.

Hardware* warranty:

Two (2) year limited warranty on all parts and labor for Vaddio manufactured

products. Vaddio warrants its manufactured products against defects in materials and workmanship for a
period of two years from the day of purchase, to the original purchaser, if Vaddio receives notice of such
defects during the warranty. Vaddio, at its option, will repair or replace products that prove to be
defective. Vaddio manufactures its hardware products from parts and components that are new or
equivalent to new in accordance with industry standard practices.

Exclusions:

 The above warranty shall not apply to defects resulting from improper or inadequate

maintenance by the customer, customers applied software or interfacing, unauthorized modifications or
misuse, mishandling, operation outside the normal environmental specifications for the product, use of the
incorrect power supply, modified power supply or improper site operation and maintenance. OEM and
special order products manufactured by other companies are excluded and are covered by the
manufacturer’s warranty.

Vaddio Customer Service:

 Vaddio will test, repair, or replace the product or products without charge if the

unit is under warranty.  If the product is out of warranty, Vaddio will test then repair the product or
products. The cost of parts and labor charge will be estimated by a technician and confirmed by the
customer prior to repair. All components must be returned for testing as a complete unit. Vaddio will not
accept responsibility for shipment after it has left the premises.

Vaddio Technical Support:

 Vaddio technicians will determine and discuss with the customer the criteria

for repair costs and/or replacement. Vaddio Technical Support can be contacted by email at

[email protected]

or by phone at one of the phone numbers listed on

support.vaddio.com

.

Return Material Authorization (RMA) number:

 Before returning a product for repair or replacement

request an RMA from Vaddio’s technical support. Provide the technician with a return phone number, e-
mail address, shipping address, product serial numbers and original purchase order number. Describe the
reason for repairs or returns as well as the date of purchase. See the General RMA Terms and Procedures
section for more information. RMAs are valid for 30 days and will be issued to Vaddio dealers only. End
users must return products through Vaddio dealers. Include the assigned RMA number in all
correspondence with Vaddio. Write the assigned RMA number clearly on the shipping label of the box when
returning the product. All products returned for credit are subject to a restocking charge without
exception. Special order product are not returnable. 

Voided varranty:

 The warranty does not apply if the original serial number has been removed or if the

product has been disassembled or damaged through misuse, accident, modifications, use of incorrect
power supply, use of a modified power supply or unauthorized repair.

Shipping and handling:

 Vaddio will not pay for inbound shipping transportation or insurance charges or

accept any responsibility for laws and ordinances from inbound transit. Vaddio will pay for outbound
shipping, transportation, and insurance charges for all items under warranty but will not assume
responsibility for loss and/or damage by the outbound freight carrier. If the return shipment appears
damaged, retain the original boxes and packing material for inspection by the carrier. Contact your carrier
immediately.

Products not under warranty:

Payment arrangements are required before outbound shipment for all out of

warranty products. 

31

Configuration and Administration Guide for the ConferenceSHOT 10 Enterprise-Class PTZ Conferencing Camera

Summary of Contents for ConferenceSHOT 10

Page 1: ...Configuration and Administration Guide for ConferenceSHOT 10 Enterprise Class PTZ Conferencing Camera Document 411 0002 32 Rev B January 2017...

Page 2: ...era to a Preset Position 12 Store a Camera Preset 13 Change the Focus 14 Change the Speed of Camera Movements 14 Set Pan Direction 15 Web Tasks for Administrators Managing Access and Passwords 16 Web...

Page 3: ...Web Tasks for Administrators Viewing Diagnostic Logs 25 Troubleshooting and Care 26 Status Light 27 Restoring Default Camera Settings 28 Operation Storage and Care 28 Compliance Statements and Declar...

Page 4: ...mera It includes unpacking and installation as well as specifications and reference sections on Telnet and RS 232 commands Features n PTZ camera for huddle rooms and small to medium conference rooms n...

Page 5: ...urrent state Back of the Camera n 12 VDC 3 0 Amp power connector Connect only the power supply shipped with the camera n USB 3 0 type B video device connector Streams uncompressed UVC standard video n...

Page 6: ...k red Move the camera to a preset position Position Preset buttons 1 through 6 bottom two rows Focus the camera Auto Focus button near arrow buttons Manual Focus buttons Near and Far below Zoom Speed...

Page 7: ...ately to its home and preset positions Auto Focus Switch the camera to Auto Focus mode Zoom Speed Select Slow or Fast movements for telephoto and wide angle shots n T slow and fast Telephoto n W slow...

Page 8: ...it In the absence of a DHCP server the camera s default IP address is 169 254 1 1 and its subnet mask is 255 255 0 0 You can configure the camera s static IP address either through the network or fro...

Page 9: ...ord is password Only the camera control page is available with user level access If you are not logged in using the admin account the Admin button on the Camera Controls page opens the admin login dia...

Page 10: ...t configuration n Security Set passwords and manage guest access n Diagnostics View or download logs when troubleshooting issues n System View firmware version and switch settings reboot restore facto...

Page 11: ...e balance backlight compensation Camera Settings Camera behavior n Normal or super wide mode n Status light color scheme Pro A V or UC n UVC Compliant or Client Custom USB streaming System DIP Switche...

Page 12: ...et to factory defaults System Firmware Firmware n Current version information n Save export and restore import configuration n Firmware update System Firmware Vaddio Technical Support contact informat...

Page 13: ...ive camera video video mute n Put the camera in standby or bring it back to the ready state n Focus manually or set auto focus n Set speeds for camera movements n Set or move to camera presets n Set t...

Page 14: ...eo with a message that the video is muted Manage the Camera Ready State Use the Standby button to switch between low power standby and ready states In standby mode the button is red and the screen pre...

Page 15: ...on to zoom in and the Zoom button to zoom out Move the Camera to a Preset Position Use the numbered Preset buttons to move the camera to any of its programmed positions If you select a preset that has...

Page 16: ...logged in as admin this box provides the option to store the shot as a numbered preset or as the Home position 3 To save the current CCU settings along with the camera position check Store with Curre...

Page 17: ...nized when the Auto Focus box is checked Change the Speed of Camera Movements Use the speed sliders to adjust the speed of movements that you control with the buttons for pan tilt and zoom For tight s...

Page 18: ...mera and use the left arrow button the camera pans to your right To switch the camera pan direction to the near end point of view use the Settings button to open the pan and tilt direction box Then se...

Page 19: ...or not by default inactive sessions expire after 30 minutes Note For best security Vaddio strongly recommends changing the user and admin passwords Using the default passwords leaves the product vuln...

Page 20: ...Set up other networking information if using static IP addressing Network Configuration You will be able to enter the IP address subnet mask and gateway only if you set IP Address to Static Note DHCP...

Page 21: ...able enable Automatic NTP Updating 2 Select the desired time zone from the list 3 If desired specify the NTP server to use If you are not sure about this use the default 18 Configuration and Administr...

Page 22: ...or IP streaming n Specify the IP streaming port and path URL After making changes on this page save them Edit the USB Device Name To change the way the camera shows up in your soft client s camera sel...

Page 23: ...uality mode only Select the desired IP streaming frame rate 5 Custom quality mode only Select Constant or Variable bit rate 6 Custom quality mode Variable bit rate only Set the Quality Quantization sl...

Page 24: ...light Compensation reduces the contrast between extremes and Wide Dynamic Range increases it they cannot be used together 3 To allow the camera to adjust the white balance automatically check the Auto...

Page 25: ...he Camera This can help if the camera stops responding as you expect In the System Utilities section click Reboot Save and Import or Restore a Configuration If you need to configure several cameras th...

Page 26: ...pens and the indicator light on the front of the camera turns yellow to show the firmware update is in progress If the update process presents warnings or error messages read them carefully The camera...

Page 27: ...at meets your needs The Pro AV color scheme matches the color scheme used in Vaddio s non USB cameras USB stream format UVC Compliant or Client Custom Client Custom enables far end camera control when...

Page 28: ...ormation for contacting Vaddio Technical Support on the Help screen Web Tasks for Administrators Viewing Diagnostic Logs If you encounter a problem that you can t solve your Vaddio technical support r...

Page 29: ...ng the IP address you browsed to Press the Data Screen button on the remote to see camera information The camera s web UI is available but the camera does not respond to commands via RS 232 connection...

Page 30: ...ibrate This takes a few seconds Status Light The light in the camera s base indicates its current state n Blue Camera is active n Purple Standby mode or booting n Yellow Firmware update is in progress...

Page 31: ...orage and Care For smears or smudges on the product wipe with a clean soft cloth Use a lens cleaner on the lens Do not use any abrasive chemicals Keep this device away from food and liquids Do not ope...

Page 32: ...rence to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his her o...

Page 33: ...2006 Electrical Fast Transients EN 61000 4 5 2006 Surge Immunity EN 61000 4 6 2009 Conducted Immunity EN 61000 4 8 2010 Power Frequency Magnetic Field EN 61000 4 11 2004 Voltage Dips Interrupts and F...

Page 34: ...ent Vaddio Technical Support can be contacted by email at support vaddio com or by phone at one of the phone numbers listed on support vaddio com Return Material Authorization RMA number Before return...

Page 35: ...nstant Bit Rate 20 custom home position 13 D default IP address 5 default settings restoring 28 detail setting 21 DHCP 17 diagnosing issues 26 diagnostic logs 25 Diagnostics page web 25 DIP switches 2...

Page 36: ...ace 8 R ready state 11 rebooting the camera 22 recalibration pan and tilt 27 red gain 21 remote control 3 4 resolution 19 20 IP streaming 19 20 USB streaming 19 restoring a configuration 22 restoring...

Page 37: ...Quality IP streaming setting 20 virtual DIP switches 24 W warranty 31 web browsers supported 5 web interface 7 10 16 17 19 21 22 25 Camera Control page 10 Camera Settings page 21 Diagnostics page 25 H...

Page 38: ...s manuals technical support information and more Vaddio ConferenceSHOT RoboSHOT and EasyUSB are trademarks or registered trademarks of Milestone AV Technologies All other brand names or marks are used...

Reviews: