The pump will not
start (no water is
being pumped and
it is not making
any noise).
There may be
no power supply
to the pump.
1. Ensure that the power is turned on and
check the connection to the power point.
2. Fuse may have blown. Contact a
pump technician or contact your local
Reece branch to replace fuse.
3. Electrical power line may
have been damaged.
The pump motor
protection may
have tripped.
There may be resistance in the pump motor shaft.
1. Disconnect all electrical power.
2. Remove pump casing and check for objects
jammed between moving components.
3. If still jammed, or damaged, replacement
parts required. Contact a pump technician
or call your local Reece branch.
Check that the pump motor is not
blocked by external objects that are
causing the pump to seize.
1. Disassemble pipework and pump housing.
2. Clean impellers.
It is recommended to call a pump
technician or licensed professional.
Check that the power cables and relative
connections are not damaged.
Check if the pump winding is damaged
and replace if necessary.
This should only be done by
a qualified electrician.
If a pressure controller has been installed,
check that it is functioning correctly
and turning the pump off at no flow.
30
VADA FLOW BOSS
SUBMERSIBLE PUMP
VFB-S35
INSTALLATION MANUAL
TROUBLESHOOTING
Having trouble? Sort it out here, quick smart.
If these solutions do not solve the problem, please visit your local Reece Irrigation & Pools branch.
SYMPTOM
CAUSE
SOLUTION
Summary of Contents for VFB-S35
Page 1: ...SUBMERSIBLE PUMP INSTALLATION MANUAL VFB S35...
Page 44: ......