11
10
VADA
SUMP PUMP WITH VERTICAL FLOAT
V-150VF
INSTALLATION MANUAL
iii. Wrap a 32mm MI valve socket in
Teflon tape then connect it to the
pump outlet.
iv. Connect your pipework, ensuring
you include a barrel union for easy
maintenance.
b. If you are using a flexible
discharge hose:
i. Secure the hose to the sump pump
outlet and check valve by using hose
barbs and hose clamps (provided).
Note:
The outlet is 32mm. Use one of the hose
barbs provided to suit your set up.
4. Check that all pipework is supported
independently from the pump.
PART 3: ELECTRICAL
SET UP
It’s time to power up!
1. Ensure the power supply cord is supported
by the delivery pipes at 3 metre intervals.
2. Ensure the powerpoint is in a dry and flood
free location.
3. Plug the power supply cord into the
10 Amp powerpoint. Do not switch on.
Note:
Supply voltage that is outside the
limits specified can cause the motor to
overheat leading to overload tripping, reduced
component life or seriously damage pump,
voiding warranty.
Note:
For additional protection, the pump
must be supplied from an outlet protected
by a residual current device – RCD (also known
as an Electrical Leakage Circuit breaker –
ELCB) with a maximum rated residual current
of 30mA.
INSTALLATION
3 metres
OFF
OFF
In accordance with AS 3350.2.41
we are obliged to inform you
that this pump is not to be used
by children or infirm persons and
must not be used as a toy.