VADA V-150VF Installation Manual Download Page 6

11

10

VADA 

SUMP PUMP WITH VERTICAL FLOAT

 

V-150VF 

INSTALLATION MANUAL

 

  iii.  Wrap a 32mm MI valve socket in 

Teflon tape then connect it to the 
pump outlet.

 

  iv.  Connect your pipework, ensuring 

you include a barrel union for easy 
maintenance.

 

b.   If you are using a flexible  

discharge hose: 

 

  i.   Secure the hose to the sump pump 

outlet and check valve by using hose 
barbs and hose clamps (provided). 

Note: 

The outlet is 32mm. Use one of the hose 

barbs provided to suit your set up.

4.  Check that all pipework is supported 

independently from the pump. 

PART 3: ELECTRICAL  

SET UP 

It’s time to power up!

1.  Ensure the power supply cord is supported 

by the delivery pipes at 3 metre intervals.

2.  Ensure the powerpoint is in a dry and flood 

free location.

3.  Plug the power supply cord into the  

10 Amp powerpoint. Do not switch on.

Note: 

Supply voltage that is outside the 

limits specified can cause the motor to 
overheat leading to overload tripping, reduced 
component life or seriously damage pump, 
voiding warranty.

Note: 

For additional protection, the pump 

must be supplied from an outlet protected  
by a residual current device – RCD (also known 
as an Electrical Leakage Circuit breaker – 
ELCB) with a maximum rated residual current 
of 30mA.

INSTALLATION

3 metres

OFF

OFF

In accordance with AS 3350.2.41 
we are obliged to inform you 
that this pump is not to be used 
by children or infirm persons and 
must not be used as a toy.

Summary of Contents for V-150VF

Page 1: ...SUMP PUMP WITH VERTICAL FLOAT INSTALLATION MANUAL V 150VF...

Page 2: ...invoice number Product serial number Product model number A smooth day is a good day That s why Vada is dedicated to creating pump solutions that you can count on With a focus on easy selection simpl...

Page 3: ...ormance Discharge outlet connection 32mm BSP FI Suction inlet 10m Power cable Vertical float with automatic switch operation Cast iron pump housing Internal vortex impeller Built to handle clean and g...

Page 4: ...Pumping liquid containing solids larger than maximum recommended particle size 15mm Pumping liquid containing abrasive solids stones ceramics etc PREPARING FOR INSTALLATION For a successful installat...

Page 5: ...pework Ensure you have selected the position for your discharge outlet on the pit cut a hole to size on the pit and then secure a tank outlet or similar Note The length and the diameter of the dischar...

Page 6: ...wer supply cord is supported by the delivery pipes at 3 metre intervals 2 Ensure the powerpoint is in a dry and flood free location 3 Plug the power supply cord into the 10 Amp powerpoint Do not switc...

Page 7: ...of abnormal mechanical friction in the pump and or motor which may be caused by debris caught in the impeller CHECKING THE FLOW 1 Get a bucket of a known size e g 10 litre bucket and place it near the...

Page 8: ...product lifespan Note Should you require further specific information or assistance with calculating the system duty of your application please contact your local Reece branch STORING THE PUMP PRODUC...

Page 9: ...sibly looking to check that the float operation is not impaired Physically lift the float switch vertically if needed The float is caught on something and cannot rise Ensure that the float can move fr...

Page 10: ...mp is being used with clean and grey water and is NOT being used with alternative fluids specifically abrasive corrosive or explosive fluids The pump is isolated from electrical supply during installa...

Page 11: ......

Reviews: