background image

13

12

VADA 

SUMP PUMP

 

V150 

INSTALLATION MANUAL

1.   Turn the power on at the power point.

2.  Put a small amount of water in the  

tank/pit/well, enough to cover the pump 
completely. 

3.  The float switch will rise and the pump will 

start to empty the pit.

4.  As the pit empties, the float switch will fall 

and the pump will stop.

Note: 

There is a small port hole in the base of 

the pumping unit. On occasion, this will expel 
air bubbles should air become trapped within 
the pump housing. This is a normal operation.

Under normal conditions, the Vada V150 Sump 
Pump requires low maintenance and is simple 
to service.

To avoid possible failures, we recommend 
periodically checking the flow and pressure 
supplied and current absorption for the 
following:

•  A decrease in pressure. This is a symptom 

of wear.

•  An increase in current absorption. This is  

a sign of abnormal mechanical friction in the 
pump and/or motor which may be caused 
by debris caught in the impeller.

CHECKING THE FLOW

1.  Get a bucket of a known size (e.g. 10 litre 

bucket) and place it near the Sump Pump. 

2.  Get a hose and connect it from the final 

discharge point to the bucket.

3.  When the pump is operating, time how long 

it takes to fill the bucket.

4.  Enter the bucket size and time it takes  

to fill the bucket to the formula below.

 1. 

Bucket size

 x 60 = V

 

 2.   V  ÷ 

time is takes to fill the bucket

 =  

flow in litres per minute

Example: 

I am using a 

10L

 bucket.  

It takes 

8.5 seconds

 for the bucket to fill. 

 1. 

10

 x 60 = 600

 

2.  600 ÷ 

8.5

 = 70

 

Therefore, my Sump Pump is producing  
70 litres per minute. 

 

If the answer (litres per minute) is between 
64 and 96, the sump pump is operating 
within the optimum operating range.

Note: 

Optimum operating range is  

4.3–3.2 metres head, 64–96 litres per minute.

OPERATION

SERVICE & MAINTENANCE

Do not run pump dry. Ensure 
that pump is submerged in water 
before operating.

Turn off power to motor and 
remove plug from power outlet 
before working on pump or motor.

ON

Summary of Contents for SUMP PUMP V150

Page 1: ...SUMP PUMP INSTALLATION MANUAL V150...

Page 2: ...number Product serial number Product model number A smooth day is a good day That s why Vada is dedicated to creating pump solutions that you can count on With a focus on easy selection simple install...

Page 3: ...t wall HELPFUL HINT 5 4 VADA SUMP PUMP V150 INSTALLATION MANUAL KNOW YOUR PRODUCT SPECIFICATIONS Constructed from cast iron for durability and designed with a vortex impeller for improved water flow a...

Page 4: ...olids larger than maximum recommended particle size 15mm Pumping liquid containing abrasive solids stones ceramics etc What you ll need to supply The residence must also have a Residual Current Device...

Page 5: ...charge pipework Ensure you have selected the position for your discharge outlet on the pit cut a hole to size on the pit and then secure a tank outlet or similar Note The length and the diameter of th...

Page 6: ...upply cord is supported by the delivery pipes at 3 metre intervals 2 Ensure the powerpoint is in a dry and flood free location 3 Plug the power supply cord into the 10 Amp powerpoint Do not switch on...

Page 7: ...friction in the pump and or motor which may be caused by debris caught in the impeller CHECKING THE FLOW 1 Get a bucket of a known size e g 10 litre bucket and place it near the Sump Pump 2 Get a hose...

Page 8: ...uct lifespan Note Should you require further specific information or assistance with calculating the system duty of your application please contact your local Reece branch STORING THE PUMP PRODUCT DIM...

Page 9: ...t the float operation is not impaired Physically lift the float switch vertically if needed The float is caught on something and cannot rise Ensure that the float can move freely Ensure the pit size i...

Page 10: ...g used with clean and grey water and is NOT being used with alternative fluids specifically abrasive corrosive or explosive fluids The pump is isolated from electrical supply during installation and a...

Page 11: ......

Reviews: