The pump is designed to be used with clean water 

in a residential application. Do not use it with 

alternative fluids, specifically abrasive, corrosive 

or explosive fluids. Do not install or operate your 

pump in an explosive enviroment or near 

combustible matter.

Liquid may be HOT, release pressure with care 

before servicing.

The pump operator or owner must be provided 

with this owner’s manual. This must be read before 

operation, and followed during operation.

DO NOT RUN PUMP DRY

Ensure that your pump is submerged in water 

before operating.

Pump should only be serviced by qualified 

personel. For best results, use only genuine service 

parts. Be sure to prime pump before starting.

To avoid dangerous or fatal electrical shock hazard, 

turn OFF power to motor and remove plug from 

power outlet before working on pump or motor.

OPERATION

SERVICE AND MAINTENANCE

START-UP/OPERATION CHECK

When the power is turned on, put a small amount of water in the tank/pit/well, enough to cover the pump completely.  The float switch will rise, 

the pump will start and empty the pit.  As the pit emties, the float switch will fall and the pump will stop.

The system is now working correctly. If no water is delivered, check the troubleshooting section.

GENERAL CARE AND MAINTENANCE

Under normal conditions V150 pumps do not need any type of maintenance. In order to avoid possible failures, it is advisable to periodically 

check the pressure supplied and current absorption. A decrease in pressure is a symptom of wear. An increase in current absorption is a sign of 

abnormal mechanical friction in the pump and/or motor.

If the pump is not going to be used for long periods of time it should be emptied completely, rinsed with clean water and put in a dry place.