INSTALLATION

1. Locating the Pump

Using the handle at the top of the pump, connect a nylon rope (provided) or a stainless steel cable suitable to sustain it’s weight.  Anchor the 

other end of the rope or cable so that it balances the weight of the pump as it rests in it’s final position at the base of the tank/pit/well.

2. Power Source

If the pump is being installed in a permanent position arrange for an electrician to install a 10A weatherproof outdoor power point near the pump 

if there is not one there already.

3. Suction

Ensure that the float switch can move freely within the tank/well/pit and cannot become trapped.

The V150 should be positioned on a hard surface that is elevated from the base of of the tank/pit/well.  This is to ensure that pumped water is free 

of sediment which may be present at the base.

4. Discharge

It is advisable to fit a check valve on the discharge piping to prevent fluid from re-circulating when the pump has stopped.

If you are using a hard discharge pipe, thred this into the outlet of the pump housing.  If you are using a flexible discharge hose, use hose clamps 

to secure this to the fitting provided.

The length and diameter of the discharge hoses/pipes will affect the pressure and flow rate at which your pump operates. Pressure ratings of all 

components must exceed the maximum pressure of the pump by an appropriate safety factor. All pipe work should be supported independently 

of the pump.  

ELECTRICAL INSTALLATION

In accordance with AS 3350.2.41 we are obliged 

to inform you that this pump is not to be used by 

children or infirm persons and must not be used as a 

toy by children

The pump must be supplied by an outlet protected 

by a residual current device or earth leakage circuit 

breaker with a maximum rated residual current of 

30mA

The pump is supplied with a standard Australian 10 Amperes plug and cord. Connection to the power supply is a matter of inserting the plug into 

the suitable power point. 

Before plugging the power supply cord into the power point, ensure that the power supply cord is supported by the delivery pipes at 3 meter 

intervals.

The pump will operate when the float is higher than level and stop when the pump float is in the low position.

Supply voltage outside limits specified in Model Data can cause motor overheat leading to overload tripping, reduced component life or seriously 

damage pump and voids warranty.

For additional protection, the pump must be supplied from an outlet protected by a residual current device – RCD (also known as an Electrical 

Leakage Circuit breaker – ELCB) with a maximum rated residual current of 30mA.