QUALITY CONTROL 

All Vacuvent air valves conform to a stringent set of criteria before leaving the factory. 

All valves are tested for full functionality and corrosion protection quality before being released by 

the in-house quality manager. 

Corrosion protection is of the highest quality and the mild steel components are fusion bonded 

epoxy coated. Threaded components interacting with the fusion bonded epoxy coated parts are wet 

assembled using a two pack epoxy approved for use in potable water. 

Quality control documents and material data sheets can be made available on request with 

purchase. 

The Vacuvent series VA air valve has very little that can corrode and is prepared for active duty in 

water delivery pipelines. 

GENERAL DESCRIPTION 

The Vacuvent - VA anti-shock series of air valves are intended to reduce the risks associated with 

pressure variance in pipelines. Surge and water hammer will always be present in fluid transporting 

pipelines; the intent of the Vacuvent air valve is to effectively manage the affects thereof in liquid 

transporting pipelines. 

When water drains from the pipeline, the VA series air valve opens to allow atmospheric air to force 

its way into the pipeline, preventing a negative pressure forming inside the pipeline. This allows for 

designers to reduce wall thicknesses in their pipes as negative pressure will not have such a 

substantial effect on the line. 

During filling or introduction of air into a pipeline the Vacuvent VA series anti shock air valve will 

throttle the outgoing air via the small orifice and anti-shock orifice. Pressure is regulated via a 

pneumatic relay between the small orifice and the much larger anti-shock orifice. This system will 

ensure that air is drained from the pipeline. 

Where necessary an optional - full stainless steel - body construction can be specified. 

Before being packaged all Vacuvent air valves have to pass functional tests such that it is ensured 

that they will function fully upon delivery. 

Summary of Contents for VA Series

Page 1: ...AIR RELEASE AND VACUUM BREAK VALVES SERIES VA OWNER S MANUAL...

Page 2: ...neral Specification 5 General Specification 6 Quality Control 10 General Description 10 Functional Testing and Overall Inspection 11 Corrosion Protection 11 Shipping 11 Installation Removal and Storag...

Page 3: ...for the installation maintenance and general care required by the air valve to produce optimum results for the end user Your Vacuvent air valve should function flawlessly for many years as it is virtu...

Page 4: ...all and large orifice with Anti Shock Orifice Mechanism End Connection Screwed BSP or NPT male Nominal Size DN25 1 and DN50 2 Model No s See Table Operating Pressure PN25 0 5 bar 7 2 psi 25 bar 363 ps...

Page 5: ...d Connection Flanged for alignment to BS 4504 PN10 PN16 PN25 or PN40 SANS 1123 T1000 3 T1600 3 T2500 3 or T4000 3 ANSI B16 1 Class150 or ANSI B16 5 Class 300 Nominal Size DN150 and DN200 Model No s Se...

Page 6: ...m End Connection Flanged for alignment to BS 4504 PN10 PN16 PN25 or PN40 SANS 1123 T1000 3 T1600 3 T2500 3 or T4000 3 ANSI B16 1 Class150 or ANSI B16 5 Class 300 Nominal Size DN150 and DN200 Model No...

Page 7: ...Independent Valve Marketing Pty Ltd Engineering Page 7 of 18 VSS0203WD00...

Page 8: ...Independent Valve Marketing Pty Ltd Engineering Page 8 of 18 VSS0203WD00...

Page 9: ...Independent Valve Marketing Pty Ltd Engineering Page 9 of 18 VSS0203WD00...

Page 10: ...re variance in pipelines Surge and water hammer will always be present in fluid transporting pipelines the intent of the Vacuvent air valve is to effectively manage the affects thereof in liquid trans...

Page 11: ...eline under pressure Criteria Small orifice release of air up to working pressure Anti shock opening up to working pressure 5 Visual Inspection Purpose Ensure quality of the product Criteria No visibl...

Page 12: ...cumulator facilitates the effective introduction of air into a draining pipeline If an accumulator is not used the incoming air may be swept away before effectively vented Figure 4 Air Valve Arrangeme...

Page 13: ...ring the air valve firmly DO NOT USE A PIPE WRENCH ON THE AIR VALVE AND ON THE BARREL OF THE AIR VALVE THIS MAY RESULT IN DAMAGE TO THE COATING AND OR MECHNICAL DAMAGE TO THE AIR VALVE FLANGED TYPE Fl...

Page 14: ...alculated by adding all the valves on that section Exhaust however is another matter and it s feasible in some instances to add all the anti shock capabilities for one section It s also important to e...

Page 15: ...to protect the pipeline and seals from low pressure within the pipeline during draining or other pipeline disturbances e g pump trip One accepted method is to limit the internal pressure to 3 5 m P 5...

Page 16: ...shock orifice item 2 through the upper float This discharge will be sufficient for the pressurised air to evacuate the valve and the pipeline This type of valve operation is validated by Surge Analys...

Page 17: ...ove figure one can see the air accumulating in the valve with the pipeline under pressure generally only when small amounts of air enters the valve through the pressurized system again this operation...

Page 18: ...one valve with its smart anti shock will fulfil the functions of several different valves without modification or ad ons CONTACT DETAILS Feel free to contact us regarding your Vacuvent valve should yo...

Reviews: