10
Programing Remote Control Fob
Your remote control Fob has already been programmed at the factory. Follow this procedure
if reprogramming becomes necessary, due to Fob replacement or after changing the Fob’s battery.
1.
Disconnect Tester from power.
2.
Connect Tester to workshop air.
3.
While pressing and holding the
SET PRESSURE
arrow
UP
button on the Tester:
connect Tester to power.
4.
When
Utl
(Utilities) is displayed; release arrow UP button.
NOTE: “
Pr9
” (Program) is displayed.
5.
Momentarily press the red button on the Remote Fob and release. After two seconds press the red
button again and release.
NOTE: The display will now read “
End
”, indicating the remote is now programmed to the Tester.
6.
Disconnect and reconnect Tester from power to resume normal operations.
Setting Pressure Reading Default to PSI or BAR
Your Tester has been preset at the factory to either default to PSI or BAR readings. Follow the steps below
to change the default setting.
1.
Disconnect Tester from power.
2.
Connect Tester to workshop air.
3.
While pressing and holding the
SET PRESSURE
arrows
UP
/
DOWN
buttons on the Tester:
connect Tester to power.
4.
When
Utl
(Utilities) is displayed; release UP / DOWN arrow buttons.
5.
Push start button until you see
PSI
(or until you see
bAr
, if system is preset to PSI).
6.
Push arrow button
DOWN
once to read
bAr
(or to read PSI, if system is preset to bar).
7.
Push start.
Disconnect and reconnect Tester from power to resume normal operations.