6
Quick Start Guide
1
.
Connect Tester to either compressed air or any inert gas, such as nitrogen.
NOTE: When using inert gas; you must regulate the pressure exiting the
gas tank, prior to connecting to the WV711 Tester!
Compressed air or nitrogen tank pressure to the Tester can be between
50-175 PSI (3.4 to 12 bar). The internal pressure regulator in the WV711 Tester
sets the test pressure 3-43.5 PSIG (
0.21 to
3 bar), according to your settings.
2
.
a) Connect power cord onto back of Tester.
c) To remove: pull white tab.
b) Push white tab forward to locked position.
d) Push inner section downward,
while at the same time pulling
plug away from Tester.
a
b
c
d
Or
Regulator
(WVA-051)
Pressure line
from
Regulator to
Tester
Compressed air
Inert gas tank
Regulator not
required if air supply
is between 50-175 PSI.